EJA440A高静压压力变送器怎么样?

EJA440A高静压压力变送器怎么样?

描述图片1


EJA440A高静压压力变送器怎么样?_第1张图片

Supply Voltage “�”

10.5 to 42 V DC for general use and flameproof type

10.5 to 32 V DC for lightning protector (Optional

code /A)

10.5 to 30 V DC for intrinsically safe, Type n,

nonincendive, or non-sparking type

Minimum voltage limited at 16.4 V DC for digital

communications, BRAIN and HART

Load (Output signal code D and E)

0 to 1335  for operation

250 to 600  for digital communication

EMC Conformity Standards “�” ,

EN61326-1 Class A, Table2 (For use in industrial

locations)

EN61326-2-3

European Pressure Equipment Directive 97/23/EC

Sound Engineering Practice

With option code /PE3

Category III, Module H, Type of Equipment: Pressure

Accessory-Vessel, Type of Fluid: Liquid and Gas,

Group of Fluid: 1 and 2

Safety Requirement Standards

EN61010-1

? Altitude of installation site: Max. 2,000 m above sea level

? Installation category: I

? Pollution degree: 2

? Indoor/Outdoor use

Communication Requirements “�”

BRAIN

Communication Distance

Up to 2 km (1.25 miles) when using CEV polyethylene-insulated

PVC-sheathed cables. Communication

distance varies depending on type of cable used.

Load Capacitance

0.22 �F or less (see note)

Load Inductance

3.3 mH or less (see note)

Spacing from power line

15 cm or more.

Input Impedance of communicating device

10 k or more at 2.4 kHz.

Note : For general-use and Flameproof type.

For Intrinsically safe type, please refer to

‘OPTIONAL SPECIFICATIONS.’

小型轻量设计

由于采用ASIC放大器设计使包装变小,罗斯蒙特3051 以及膜盒构造和法兰的小型化,这款机型的重量降到了原有机型的一半。ASIC设计不仅减少了零件数量,而且提高了放大器的可靠性。

- 现场总线通信能力

现场总线是双向数字通信系统,是配置仪表控制系统的革新技术,同时也是前景很好的更新换代产品,用于替换现在现场仪表中广泛使用的标准4~20mA模拟通信。

EJA系列提供两种现场总线模式,FOUNDATION?现场总线低压模式和PROFIBUS PA设备,以实现横河电机和其他供应商的协同工作。软件方面,EJA系列采用两个AI功能块计算差压和静压,从而实现灵活的仪表配置。

规格

EJA440A压力变送器

C膜盒 D膜盒

测量范围 -0.1~32MPa

(-15~4500psi) -0.1~50MPa

(-15~7200psi)

测量量程 5~32MPa

(720~4500psi) 5~50MPa

(720~7200psi)

精度 ±0.12% ±0.12%

防护等级 IP67,NEMA 4X,和JIS C0920防浸型

防爆规格 FM,CENELEC ATEX,CSA,IECEx

输出信号 4~20mA DC或FOUNDATION?现场总线或PROFIBUS PA两线制数字通信

电源 BRAIN和HART:10.5~42V DC (本安型: 10.5~30V DC)

Fieldbus:9~32V DC (本安Entity模式9~24V DC,本安FISCO模式9~17.5V DC)

环境温度 -40~85℃ (-40~185℃) (普通型)

-30~80℃ (-22~176℃) (内藏指示器)

过程温度 -40~120℃ (-40~248℃) (普通型)

罗斯蒙特 最大过压 48MPa (6750psig) 60MPa (8500psig)

安装 2-inch管安装

接液部件材质 膜盒 SUS316L (膜片: 哈氏合金C-276)

容室法兰 SUS316

外壳 铝合金或SUS316不锈钢(可选)

产品图片2


EJA440A高静压压力变送器怎么样?_第2张图片