SUN平台新装完PowerPath之后,一定要确认路径Policy的状态,需要改为CLAROpt的双Active模式(加入License之后)!

步骤如下:
     另外,在没有安装PP软件之前,format的输出中,OS只能够发现一般的路径和硬盘,另外一般的硬盘类型是Unknow的状态。

root@sun1  # /etc/powermt display dev=all
Pseudo name=emcpower0a
CLARiiON ID=CK200074900142 [emc3]
Logical device ID=6006016015D21E006FA82325 D019DD11 [LUN 2]
state=alive;   policy=BasicFailover; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host ---------------     - Stor -     -- I/O Path -   -- Stats ---
### HW Path                                 I/O Paths       Interf.     Mode       State   Q-IOs Errors
==============================================================================
3074   ssm@0/pci@18/SUNW,qlc@1     c3t5006016041E04ED6d0s0 SP A0         active   alive           0           0
3074   ssm@0/pci@18/SUNW,qlc@1     c3t5006016841E04ED6d0s0 SP B0         active   alive           0           0
3072   ssm@0/pci@19/SUNW,qlc@2     c4t5006016141E04ED6d0s0 SP A1         unlic     alive           0           0
3072   ssm@0/pci@19/SUNW,qlc@2     c4t5006016941E04ED6d0s0 SP B1         unlic     alive           0           0
 
root@sun1  # /etc/powermt set policy=co
Error: "co" is not a valid policy for CLARiiON storage systems with the installed license.
#添加License之前的修改,会去check license的状态。报错!!

root@sun1  # /sbin/emcpreg -add BSPO-FB4R-MFZK-QAOZ-MH9Y-6N79
1 key(s) successfully added.
 

查看PowerPath的sn:
emcpreg -list

root@sun1  # powermt set policy=co
 

root@sun1  # powermt display dev=all
Pseudo name=emcpower0a
CLARiiON ID=CK200074900142 [emc3]
Logical device ID=6006016015D21E006FA82325 D019DD11 [LUN 2]
state=alive;   policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host ---------------     - Stor -     -- I/O Path -   -- Stats ---
### HW Path                                 I/O Paths       Interf.     Mode       State   Q-IOs Errors
==============================================================================
3074   ssm@0/pci@18/SUNW,qlc@1     c3t5006016041E04ED6d0s0 SP A0         active   alive           0           0
3074   ssm@0/pci@18/SUNW,qlc@1     c3t5006016841E04ED6d0s0 SP B0         active   alive           0           0
3072   ssm@0/pci@19/SUNW,qlc@2     c4t5006016141E04ED6d0s0 SP A1         active   alive           0           0
3072   ssm@0/pci@19/SUNW,qlc@2     c4t5006016941E04ED6d0s0 SP B1         active   alive           0           0