光模块总结
一、光模块基础知识
1.光传输的优势:
(1)传输容量大
(2)传输损耗低
(3)抗电磁干扰
(4)信道之间干扰小,保密性好
(5)光纤介质轻便,便于理线
2.光模块:实现光电转换和电光转换功能的光电子器件
具体包括:光发送模块Transmitter、光接收模块Receiver、光收发一体模块Transceiver和光转发模块Transponder,通常说的光模块指光收发一体模块。
3.工作原理
发送接口输入一定码率的电信号,经过内部的驱动芯片处理后由驱动半导体激光器(LD)或者发光二极管(LED)发射出相应速率的调制光信号,通过光纤传输后,接收接口再把光信号由光探测二极管转换成电信号,并经过前置放大器后输出相应码率的电信号。
4.关键参数指标
光模块的关键技术指标主要包含:发送光功率、接收光功率、过载光功率、接收灵敏度最大值、消光比。
二、交换机上光模块信息示例
1.华为设备接口光模块信息
[huawei] display interface 100GE 1/0/0 transceiver verbose
100GE1/0/0 transceiver information:
-------------------------------------------------------------------
Common information:
Transceiver Type :100GBASE_CWDM4
Connector Type :LC
Wavelength (nm) :1301
Transfer Distance (m) :2000(9um/125um SMF)
Digital Diagnostic Monitoring :YES
Vendor Name :XXX
Vendor Part Number :XXXX
Ordering Name :
-------------------------------------------------------------------
Manufacture information:
Manu. Serial Number :XXXXX
Manufacturing Date :2017-11-2+08:00
Vendor Name :FINISAR CORP.
-------------------------------------------------------------------
Alarm information:
Non-Huawei-Ethernet-Switch-Certified Transceiver
-------------------------------------------------------------------
Diagnostic information:
Temperature (Celsius) :38.64
Voltage (V) :3.25
Bias Current (mA) :40.23|36.02 (Lane0|Lane1)
36.68|36.97 (Lane2|Lane3)
Bias High Threshold (mA) :55.00
Bias Low Threshold (mA) :25.00
Current RX Power (dBm) :-1.05|-1.02 (Lane0|Lane1)
0.14|0.01 (Lane2|Lane3)
Default RX Power High Threshold (dBm) :3.50
Default RX Power Low Threshold (dBm) :-16.00
Current TX Power (dBm) :0.72|-0.14 (Lane0|Lane1)
-0.48|0.55 (Lane2|Lane3)
Default TX Power High Threshold (dBm) :5.50
Default TX Power Low Threshold (dBm) :-8.00
-------------------------------------------------------------------
Common information |
表示光模块的常规信息。 |
Transceiver Type |
表示光模块类型。 |
Connector Type |
表示接口类型。 |
Wavelength (nm) |
表示光波波长。 |
Transfer Distance (m) |
表示光波传输距离。50um/125um表示光纤的直径,OM2表示光纤的等级。 |
Digital Diagnostic Monitoring |
表示光模块诊断信息是否监控。 |
Vendor Name |
表示光模块制造厂商名称。 |
Vendor Part Number |
表示光模块制造厂商编号。 |
Ordering Name |
表示光模块对外型号 |
Manufacture information |
表示光模块制造信息 |
Manu. Serial Number |
表示光模块生产序列号。 |
Manufacturing Date |
表示光模块生产日期。 |
Alarm information |
表示光模块告警信息。 |
Diagnostic information |
表示光模块诊断信息。如果显示为“-”,则表示该光模块不支持获取此信息或信息不精确。 |
Temperature (Celsius) |
表示光模块当前温度。 |
Voltage(V) |
表示光模块当前电压。 |
Bias Current (mA) |
表示光模块当前电流。 |
Bias High Threshold (mA) |
表示光模块电流上限。 |
Bias Low Threshold (mA) |
表示光模块电流下限。 |
Current RX Power (dBm) |
表示当前光模块接收功率。 |
Default RX Power High Threshold (dBm) |
表示默认光模块接收功率上限。 |
Default RX Power Low Threshold (dBm) |
表示默认光模块接收功率下限。 |
Current TX Power (dBm) |
表示当前光模块发送功率。 |
Default TX Power High Threshold (dBm) |
表示默认光模块发送功率上限。 |
Default TX Power Low Threshold (dBm) |
表示默认光模块发送功率下限。 |
2.华三设备接口光模块信息
# 查看接口光模块信息
[H3C]display transceiver interface HundredGigE 6/0/1
HundredGigE6/0/1 transceiver information:
Transceiver Type : 100G_CWDM4_FEC_QSFP28
Connector Type : LC
Wavelength(nm) : 1301
Transfer Distance(km) : 2(SMF)
Digital Diagnostic Monitoring : YES
Vendor Name : XXXX
#查看接口光模块诊断信息
[H3C]display transceiver diagnosis interface HundredGigE 6/0/1
HundredGigE6/0/1 transceiver diagnostic information:
Current diagnostic parameters:
[module] Temp.(oltage(V)
31 3.31
[channel] Bias(mA) RX power(dBm) TX power(dBm)
1 39.71 -0.91 -0.72
2 36.20 -0.97 -0.39
3 36.22 -0.49 0.65
4 36.45 -0.74 0.02
Alarm thresholds:
Temp.(oltage(V) Bias(mA) RX power(dBm) TX power(dBm)
High 75 3.63 55.00 3.50 5.50
Low -5 2.97 25.00 -16.00 -8.00
3.锐捷设备接口光模块信息
Ruijie# show interface hundredGigabitEthernet 0/49 transceiver
Transceiver Type : 100GBASE-SR4-QSFP28
Connector Type : MPO
Wavelength(nm) : 850
Wavelength tolerance(nm): (+/-)10
Transfer Distance :
50/125 um OM3 fiber
-- 70m
50/125 um OM4 fiber
-- 100m
Digital Diagnostic Monitoring : YES
Vendor Serial Number : XXXX
Current diagnostic parameters[C1:Channel-1 C2:Channel-2 C3:Channel-3 C4:Channel-4 AP:Average Power]:
Temp(Celsius) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
47(OK) 3.34(OK) 7.70(OK)[C1] -0.42(OK)[C1/AP] -1.90(OK)[C1]
7.70(OK)[C2] -0.19(OK)[C2/AP] -1.80(OK)[C2]
7.70(OK)[C3] -0.18(OK)[C3/AP] -1.90(OK)[C3]
7.70(OK)[C4] -0.08(OK)[C4/AP] -2.46(OK)[C4]
Transceiver current alarm information:
None
4.思科设备接口光模块信息
Cisco# show int ethernet 1/50 transceiver details
Ethernet1/50
transceiver is present
type is QSFP-100G-SR4
name is XXXX
part number is XXX
revision is 1A
serial number is XXXX
nominal bitrate is 25500 MBit/sec per channel
Link length supported for 50/125um OM3 fiber is 70 m
cisco id is 17
cisco extended id number is 204
Lane Number:1 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 45.25 C 75.00 C -5.00 C 73.00 C -3.00 C
Voltage 3.24 V 3.63 V 2.97 V 3.46 V 3.13 V
Current 7.38 mA 14.99 mA 3.00 mA 12.99 mA 4.49 mA
Tx Power -0.31 dBm 3.39 dBm -10.40 dBm 2.39 dBm -8.41 dBm
Rx Power -0.06 dBm 3.39 dBm -12.36 dBm 2.39 dBm -10.31 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
三、光模块的分类与封装
目前常见光模块种类如下:400GE光模块、200GE光模块、100GE光模块、40GE光模块、25GE光模块、10GE光模块、GE光模块、FE光模块
1.按封装类型分类:传输速率越高,结构越复杂,由此产生了不同的封装方式。有SFP/eSFP、SFP+、SFP28、QSFP+、CXP、CFP、QSFP28等。
2.按模式分类:纤分为单模光纤、多模光纤。为了使用不同类别的光纤,产生了单模光模块、多模光模块。
单模光模块与单模光纤配套使用。单模光纤传输频带宽,传输容量大,适用于长距传输。
多模光模块与多模光纤配套使用。多模光纤有模式色散缺陷,其传输性能比单模光纤差,但成本低,适用于较小容量、短距传输。
中心波长指光信号传输所使用的光波段。目前常用的光模块的中心波长主要有三种:850nm 波段、1310nm 波段以及 1550nm 波段。
850nm 波段:多用于≤2km 短距离传输
1310nm 和 1550nm 波段:多用于中长距离传输,2km 以上的传输。
3.按传输距离分类:短距离光模块,一般认为2km及以下为短距离。中距离光模块,10~20km为中距离。长距离光模块:一般指传输距离为30Km以上的光模块。
4.彩色光模块主要应用于长距离的传输线路。光电模块通常称为电模块,又叫做光转电模块、RJ45模块,与光模块不同,电模块不进行光电转换。
四、光模块常见故障与使用注意事项详解
光模块常见故障
1、光模块端口被污染,会造成光模块无法正常使用。光模块端口有异物堵塞,可以通过肉眼清晰的看到故障光口被白色异物封堵,左侧为正常模块,右侧为故障模块。光纤跳线导接柱断在光模块内造成光模块损坏。
a)光模块的光口暴露在环境中,光口有灰尘进入而污染。
b)使用的光纤连接器端面已经污染,光模块的光口被二次污染。
c)带尾纤的光接头端面使用不当,比如:端面划伤等。
d)使用了劣质的光纤连接器。
2、光模块未插紧,导致光信号传输受限制;拔插不规范,导致光纤跳线导接柱断在光模块内。光模块在插上设备时必须保证插紧,卡锁卡到位。否则设备在震动、碰撞等情况下,光模块会发生瞬断、松动故障。
3、使用非标准的劣质的光纤连接器,损坏光模块。使用未倒角的非标光纤连接器在光纤拔插过程中损坏了的光模块。
4、使用劣质光纤跳线、使用破损的光纤跳线、或者光纤跳线被污染,导致光模块端口被污染。光纤跳线长时间未使用未做防护措施,光纤跳线接头积满了灰尘。使用时导致光模块端口被污染。使用破损的光纤跳线,易导致光模块损坏。
5、光模块的金手指导电金属损坏,导致光模块无法使用。不合格光模块的金手指导电金属缺失,并且光泽明显不够。
光模块使用注意事项
1、光模块在不使用时,用橡胶帽把光口堵住,以免掉进异物。
2、规范插拔,确保插紧,卡锁卡到位,避免在震动、碰撞的情况下,光模块发生瞬断、松动。
3、使用标准的光纤连接器,避免光模块的损坏。
4、使用标准的光纤跳线,长期不使用的情况下,光纤跳线必须安装防尘帽,以免在光纤跳线与光模块对接时产生光口污染。
5、检查金手指导电金属是否有损坏缺失,色泽是否够明亮。
6、光纤跳线插入光模块前,先固定好光模块的拉杆。
7、取出光模块时,一定要先拉出拉杆,再通过拉杆取出光模块,禁止暴力取出。
五、交换机光模块故障排查步骤
1、检查光纤跳线是否与光模块相符
常见的多模光纤跳线有橙色、灰色和青绿色,而且一般印有62.5/125u或50/125u字样;单模光纤跳线通常有黄色和蓝色等,一般印有9/125u或G652D等字样
2、自环检查
多模光模块发出的光为可见光,可以用肉眼观察(请勿直视发光口)光模块左边发光口为红色激光,有光表示正常工作。 单模块发出的光为不可见光,可以用跳线把光模块的发射口和接收口对接起来,如果交换机工作状态灯亮表示工作正常。
3、端口配置
如依然不能正常通讯,我们则需要做下面的配置,以H3C 5024P为例。现在我们一些常用的交换机端口为光电复用型,大多数光口仍处于关闭状态,这些需要人工把端口开启,而对于不同品牌的交换机之间的通讯,我们还需要把端口速率和工作模式强制配置成1000Mpbs和全双工模式
4、确认是否兼容
光模块通常需要写入厂商信息等,也就是我们常说的兼容性,如通讯仍不能正常,请与客服联系您的光模块是否与您的设备兼容。
六、交换机光模块常见故障
1.发现无法识别的光模块,可重新插拔或者更换光模块。
2.发现接口抖动的情况,可能原因是光模块有问题,导致接口有错误包,或者光纤有问题。
解决办法:首先查看两边收发光是否正常,其次判断两边接口下是否有error包,crc包,丢包等。一般是入方向有error包,crc包,此时可通过更换对端光模块尝试解决。
3.一般情况下,如果发现接口出方向有丢包,可通过更换光模块尝试解决。
链路down的情况,可查看是否是err-down,这种情况一般是是有错误包过多导致的,或者光纤问题。如果有错误包,可直接更换光模块尝试恢复。err-down的端口,在更换光模块后一般需要手动shutdown,no/undo shutdown才能恢复。
4.RX / TX low的情况导致接口不up的情况:
如果TX low:是本端没发光,现判断本端端口是否关闭,如果没有关闭,插拔或者更换光模块尝试解决。
如果RX low:是收光低,可能是对端光模块发光低,也可能是光纤问题,或者本端光模块可能也有问题。需要通过更换尝试解决。
通过将两个端口自环测试,可确定是光模块问题还是交换机端口有问题。
七、H3C交换机光模块故障排查实例
关闭STP
[UNIS]interface fge1/0/53
[UNIS-FortyGigE1/0/53]undo stp enable
[UNIS-FortyGigE1/0/53]exit
[UNIS]interface fge1/0/53
[UNIS-FortyGigE1/0/53]exit
[UNIS]interface fge1/0/54
[UNIS-FortyGigE1/0/54]undo stp enable
[UNIS-FortyGigE1/0/54]exit
[UNIS]dis stp
-------[CIST Global Info][Mode MSTP]-------
Bridge ID : 32768.dc2d-cbb4-ce40
Bridge times : Hello 2s MaxAge 20s FwdDelay 15s MaxHops 20
Root ID/ERPC : 32768.dc2d-cbb4-ce40, 0
RegRoot ID/IRPC : 32768.dc2d-cbb4-ce40, 0
RootPort ID : 0.0
BPDU-Protection : Disabled
BPDU Filter : Disabled
Bridge Config-
Digest-Snooping : Disabled
TC or TCN received : 2
Time since last TC : 0 days 0h:21m:57s
----[Port53(FortyGigE1/0/53)][DISABLED]----
Port protocol : Disabled
----[Port57(FortyGigE1/0/54)][DISABLED]----
Port protocol : Disabled
FortyGigE1/0/53
Current state: UP
Line protocol state: UP
IP packet frame type: Ethernet II, hardware address: dc2d-cbb4-ce40
Description: FortyGigE1/0/53 Interface
Bandwidth: 40000000 kbps
Loopback is not set
Media type is optical fiber, port hardware type is 40G_BASE_SR_BD_QSFP_PLUS
40Gbps-speed mode, full-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
Flow-control is not enabled
Maximum frame length: 13312
Allow jumbo frames to pass
Broadcast max-ratio: 100%
Unknown-multicast max-ratio: 100%
Unicast max-ratio: 100%
Known-unicast max-ratio: 100%
PVID: 1
Port link-type: Access
Tagged VLANs: None
Untagged VLANs: 1
Port priority: 0
Last link flapping: 0 hours 15 minutes 25 seconds
Last clearing of counters: Never
Current system time:2011-01-01 00:25:31
Last time when physical state changed to up:2011-01-01 00:10:05
Last time when physical state changed to down:2011-01-01 00:00:07
Peak input rate: 4 bytes/sec, at 2011-01-01 00:22:28
Peak output rate: 62 bytes/sec, at 2011-01-01 00:15:08
Last 300 seconds input: 0 packets/sec 4 bytes/sec 0%
Last 300 seconds output: 0 packets/sec 17 bytes/sec 0%
Input (total): 12 packets, 1476 bytes
0 unicasts, 0 broadcasts, 12 multicasts, 0 pauses
Input (normal): 12 packets, 1476 bytes
0 unicasts, 0 broadcasts, 12 multicasts, 0 pauses
Input: 0 input errors, 0 runts, 0 giants, - throttles
0 CRC, - frame, 0 overruns, - aborts
- ignored, - parity errors
Output (total): 354 packets, 43542 bytes
0 unicasts, 0 broadcasts, 354 multicasts, 0 pauses
Output (normal): 354 packets, 43542 bytes
0 unicasts, 0 broadcasts, 354 multicasts, 0 pauses
Output: 0 output errors, 0 underruns, - buffer failures
- aborts, - deferred, - collisions, - late collisions
- lost carrier, - no carrier
IPv4 traffic statistics:
Last 300 seconds input rate: 0 packets/sec, 0 bytes/sec
Last 300 seconds output rate: 0 packets/sec, 0 bytes/sec
Input: 0 packets, 0 bytes
Output: 0 packets, 0 bytes
IPv6 traffic statistics:
Last 300 seconds input rate: 0 packets/sec, 0 bytes/sec
Last 300 seconds output rate: 0 packets/sec, 0 bytes/sec
Input: 0 packets, 0 bytes
Output: 0 packets, 0 bytes
FortyGigE1/0/54
Current state: UP
Line protocol state: UP
IP packet frame type: Ethernet II, hardware address: dc2d-cbb4-ce40
Description: FortyGigE1/0/54 Interface
Bandwidth: 40000000 kbps
Loopback is not set
Media type is optical fiber, port hardware type is 40G_BASE_SR_BD_QSFP_PLUS
40Gbps-speed mode, full-duplex mode
Link speed type is autonegotiation, link duplex type is autonegotiation
Flow-control is not enabled
Maximum frame length: 13312
Allow jumbo frames to pass
Broadcast max-ratio: 100%
Unknown-multicast max-ratio: 100%
Unicast max-ratio: 100%
Known-unicast max-ratio: 100%
PVID: 1
Port link-type: Access
Tagged VLANs: None
Untagged VLANs: 1
Port priority: 0
Last link flapping: 0 hours 16 minutes 31 seconds
Last clearing of counters: Never
Current system time:2011-01-01 00:26:37
Last time when physical state changed to up:2011-01-01 00:10:05
Last time when physical state changed to down:2011-01-01 00:00:07
Peak input rate: 62 bytes/sec, at 2011-01-01 00:15:08
Peak output rate: 4 bytes/sec, at 2011-01-01 00:22:28
Last 300 seconds input: 0 packets/sec 3 bytes/sec 0%
Last 300 seconds output: 0 packets/sec 4 bytes/sec 0%
Input (total): 354 packets, 43542 bytes
0 unicasts, 0 broadcasts, 354 multicasts, 0 pauses
Input (normal): 354 packets, 43542 bytes
0 unicasts, 0 broadcasts, 354 multicasts, 0 pauses
Input: 0 input errors, 0 runts, 0 giants, - throttles
0 CRC, - frame, 0 overruns, - aborts
- ignored, - parity errors
Output (total): 12 packets, 1476 bytes
0 unicasts, 0 broadcasts, 12 multicasts, 0 pauses
Output (normal): 12 packets, 1476 bytes
0 unicasts, 0 broadcasts, 12 multicasts, 0 pauses
Output: 0 output errors, 0 underruns, - buffer failures
- aborts, - deferred, - collisions, - late collisions
- lost carrier, - no carrier
IPv4 traffic statistics:
Last 300 seconds input rate: 0 packets/sec, 0 bytes/sec
Last 300 seconds output rate: 0 packets/sec, 0 bytes/sec
Input: 0 packets, 0 bytes
Output: 0 packets, 0 bytes
IPv6 traffic statistics:
Last 300 seconds input rate: 0 packets/sec, 0 bytes/sec
Last 300 seconds output rate: 0 packets/sec, 0 bytes/sec
Input: 0 packets, 0 bytes
Output: 0 packets, 0 bytes
警告信息
FortyGigE1/0/53 transceiver current alarm information:
None
FortyGigE1/0/54 transceiver current alarm information:
None
日志信息
Log buffer: Enabled
Max buffer size: 1024
Actual buffer size: 512
Dropped messages: 0
Overwritten messages: 0
Current messages: 133
%Dec 31 23:59:49:633 2010 UNIS SYSLOG/6/SYSLOG_RESTART: System restarted --
UNIS Uniware Software.
%Jan 1 00:00:13:441 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=-IPAddr=; Command multicast forwarding-mode default in view system failed to be matched.
%Jan 1 00:00:13:485 2011 UNIS STP/6/STP_ENABLE: STP is now enabled on the device.
%Jan 1 00:01:12:203 2011 UNIS OPTMOD/4/MODULE_IN: FortyGigE1/0/54: The transceiver is 40G_BASE_SR_BD_QSFP_PLUS.
%Jan 1 00:01:21:856 2011 UNIS OPTMOD/4/MODULE_OUT: FortyGigE1/0/54: Transceiver absent.
%Jan 1 00:01:41:004 2011 UNIS OPTMOD/4/MODULE_IN: FortyGigE1/0/54: The transceiver is 40G_BASE_SR_BD_QSFP_PLUS.
%Jan 1 00:03:11:152 2011 UNIS OPTMOD/4/MODULE_OUT: FortyGigE1/0/54: Transceiver absent.
%Jan 1 00:03:58:454 2011 UNIS OPTMOD/4/MODULE_IN: FortyGigE1/0/53: The transceiver is 40G_BASE_SR_BD_QSFP_PLUS.
%Jan 1 00:04:09:143 2011 UNIS OPTMOD/4/MODULE_IN: FortyGigE1/0/54: The transceiver is 40G_BASE_SR_BD_QSFP_PLUS.
%Jan 1 00:05:07:833 2011 UNIS SHELL/5/SHELL_LOGIN: Console logged in from con0.
%Jan 1 00:05:35:267 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command stp disable all in view shell failed to be matched.
%Jan 1 00:06:19:751 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command undo stp global enable in view shell failed to be matched.
%Jan 1 00:06:25:925 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is system
%Jan 1 00:06:36:170 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command system view in view system failed to be matched.
%Jan 1 00:06:41:959 2011 UNIS CFGMAN/5/CFGMAN_EXIT_FROM_CONFIGURE: -Line=con0-IPAddr=**-User=**; Exit from the system view or a feature view to the user view.
%Jan 1 00:06:47:491 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command system view in view shell failed to be matched.
%Jan 1 00:06:51:724 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command system v in view shell failed to be matched.
%Jan 1 00:06:55:665 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is system
%Jan 1 00:07:03:023 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is stp dispute-protection
%Jan 1 00:07:17:009 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command stp disable all in view system failed to be matched.
%Jan 1 00:07:22:031 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command config in view system failed to be matched.
%Jan 1 00:09:23:093 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis interface brief
%Jan 1 00:09:43:842 2011 UNIS OPTMOD/4/MODULE_OUT: FortyGigE1/0/53: Transceiver absent.
%Jan 1 00:09:45:856 2011 UNIS OPTMOD/4/MODULE_OUT: FortyGigE1/0/54: Transceiver absent.
%Jan 1 00:09:49:900 2011 UNIS OPTMOD/4/MODULE_IN: FortyGigE1/0/53: The transceiver is 40G_BASE_SR_BD_QSFP_PLUS.
%Jan 1 00:09:52:549 2011 UNIS OPTMOD/4/MODULE_IN: FortyGigE1/0/54: The transceiver is 40G_BASE_SR_BD_QSFP_PLUS.
%Jan 1 00:10:05:749 2011 UNIS IFNET/3/PHY_UPDOWN: Physical state on the interface FortyGigE1/0/53 changed to up.
%Jan 1 00:10:05:751 2011 UNIS IFNET/5/LINK_UPDOWN: Line protocol state on the interface FortyGigE1/0/53 changed to up.
%Jan 1 00:10:05:752 2011 UNIS STP/6/STP_DETECTED_TC: Instance 0's port FortyGigE1/0/53 detected a topology change.
%Jan 1 00:10:05:753 2011 UNIS IFNET/3/PHY_UPDOWN: Physical state on the interface FortyGigE1/0/54 changed to up.
%Jan 1 00:10:05:753 2011 UNIS IFNET/5/LINK_UPDOWN: Line protocol state on the interface FortyGigE1/0/54 changed to up.
%Jan 1 00:10:23:105 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis interface brief
%Jan 1 00:12:09:710 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command stp enable in view system failed to be matched.
%Jan 1 00:12:13:497 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command stp in view system failed to be matched.
%Jan 1 00:12:30:388 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command stp in view system failed to be matched.
%Jan 1 00:13:20:493 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is display interface
%Jan 1 00:14:35:149 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis vlan
%Jan 1 00:14:44:739 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis stp
%Jan 1 00:15:59:893 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command interfce fge1/0/53 in view system failed to be matched.
%Jan 1 00:16:56:052 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis stp
%Jan 1 00:21:36:319 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is interface fge1/0/53
%Jan 1 00:21:51:649 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is undo stp enable
%Jan 1 00:21:54:505 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is quit
%Jan 1 00:22:05:327 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command inerface fge1/0/54 in view system failed to be matched.
%Jan 1 00:22:09:458 2011 UNIS STP/5/STP_BPDU_RECEIVE_EXPIRY: Instance 0's port FortyGigE1/0/54 received no BPDU within the rcvdInfoWhile interval. Information of the port aged out.
%Jan 1 00:22:22:988 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is interface fge1/0/54
%Jan 1 00:22:29:268 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is undo stp enable
%Jan 1 00:22:31:384 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is quit
%Jan 1 00:22:34:900 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis stp
%Jan 1 00:24:12:951 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis interface
%Jan 1 00:25:02:022 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command ace in view system failed to be matched.
%Jan 1 00:25:02:041 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command FortyGigE1/0/53 in view system failed to be matched.
%Jan 1 00:25:02:058 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Current state: UP in view system failed to be matched.
%Jan 1 00:25:02:075 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Line protocol state: UP in view system failed to be matched.
%Jan 1 00:25:02:159 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command IP packet frame type: Ethernet II, hardware address: dc2d-cbb4-ce40 in view system failed to be matched.
%Jan 1 00:25:02:192 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Description: FortyGigE1/0/53 Interface in view system failed to be matched.
%Jan 1 00:25:02:226 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Bandwidth: 40000000 kbps in view system failed to be matched.
%Jan 1 00:25:02:243 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Loopback is not set in view system failed to be matched.
%Jan 1 00:25:02:327 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Media type is optical fiber, port hardware type is 40G_BASE_SR_BD_QSFP_PLUS in view system failed to be matched.
%Jan 1 00:25:02:360 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command 40Gbps-speed mode, full-duplex mode in view system failed to be matched.
%Jan 1 00:25:02:428 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Link speed type is autonegotiation, link duplex type is autonegotiation in view system failed to be matched.
%Jan 1 00:25:02:461 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Flow-control is not enabled in view system failed to be matched.
%Jan 1 00:25:02:495 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Maximum frame length: 13312 in view system failed to be matched.
%Jan 1 00:25:02:529 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Allow jumbo frames to pass in view system failed to be matched.
%Jan 1 00:25:02:545 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Broadcast max-ratio: 100% in view system failed to be matched.
%Jan 1 00:25:02:579 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Unknown-multicast max-ratio: 100% in view system failed to be matched.
%Jan 1 00:25:02:613 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Unicast max-ratio: 100% in view system failed to be matched.
%Jan 1 00:25:02:646 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Known-unicast max-ratio: 100% in view system failed to be matched.
%Jan 1 00:25:02:647 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command PVID: 1 in view system failed to be matched.
%Jan 1 00:25:02:680 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Port link-type: Access in view system failed to be matched.
%Jan 1 00:25:02:697 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Tagged VLANs: None in view system failed to be matched.
%Jan 1 00:25:02:713 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Untagged VLANs: 1 in view system failed to be matched.
%Jan 1 00:25:02:730 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Port priority: 0 in view system failed to be matched.
%Jan 1 00:25:02:781 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last link flapping: 0 hours 14 minutes 7 seconds in view system failed to be matched.
%Jan 1 00:25:02:814 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last clearing of counters: Never in view system failed to be matched.
%Jan 1 00:25:02:865 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Current system time:2011-01-01 00:24:12 in view system failed to be matched.
%Jan 1 00:25:02:932 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last time when physical state changed to up:2011-01-01 00:10:05 in view system failed to be matched.
%Jan 1 00:25:02:999 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last time when physical state changed to down:2011-01-01 00:00:07 in view system failed to be matched.
%Jan 1 00:25:03:050 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Peak input rate: 4 bytes/sec, at 2011-01-01 00:22:28 in view system failed to be matched.
%Jan 1 00:25:03:117 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Peak output rate: 62 bytes/sec, at 2011-01-01 00:15:08 in view system failed to be matched.
%Jan 1 00:25:03:167 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last 300 seconds input: 0 packets/sec 4 bytes/sec 0% in view system failed to be matched.
%Jan 1 00:25:03:235 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last 300 seconds output: 0 packets/sec 33 bytes/sec 0% in view system failed to be matched.
%Jan 1 00:25:03:268 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Input (total): 12 packets, 1476 bytes in view system failed to be matched.
%Jan 1 00:25:03:335 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command 0 unicasts, 0 broadcasts, 12 multicasts, 0 pauses in view system failed to be matched.
%Jan 1 00:25:03:386 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Input (normal): 12 packets, 1476 bytes in view system failed to be matched.
%Jan 1 00:25:03:436 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command 0 unicasts, 0 broadcasts, 12 multicasts, 0 pauses in view system failed to be matched.
%Jan 1 00:25:03:504 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Input: 0 input errors, 0 runts, 0 giants, - throttles in view system failed to be matched.
%Jan 1 00:25:03:554 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command 0 CRC, - frame, 0 overruns, - aborts in view system failed to be matched.
%Jan 1 00:25:03:588 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command - ignored, - parity errors in view system failed to be matched.
%Jan 1 00:25:03:638 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Output (total): 354 packets, 43542 bytes in view system failed to be matched.
%Jan 1 00:25:03:689 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command 0 unicasts, 0 broadcasts, 354 multicasts, 0 pauses in view system failed to be matched.
%Jan 1 00:25:03:739 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Output (normal): 354 packets, 43542 bytes in view system failed to be matched.
%Jan 1 00:25:03:806 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command 0 unicasts, 0 broadcasts, 354 multicasts, 0 pauses in view system failed to be matched.
%Jan 1 00:25:03:857 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Output: 0 output errors, 0 underruns, - buffer failures in view system failed to be matched.
%Jan 1 00:25:03:924 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command - aborts, - deferred, - collisions, - late collisions in view system failed to be matched.
%Jan 1 00:25:03:974 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command - lost carrier, - no carrier in view system failed to be matched.
%Jan 1 00:25:03:991 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command IPv4 traffic statistics: in view system failed to be matched.
%Jan 1 00:25:04:058 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last 300 seconds input rate: 0 packets/sec, 0 bytes/sec in view system failed to be matched.
%Jan 1 00:25:04:109 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last 300 seconds output rate: 0 packets/sec, 0 bytes/sec in view system failed to be matched.
%Jan 1 00:25:04:142 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Input: 0 packets, 0 bytes in view system failed to be matched.
%Jan 1 00:25:04:176 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Output: 0 packets, 0 bytes in view system failed to be matched.
%Jan 1 00:25:04:193 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command IPv6 traffic statistics: in view system failed to be matched.
%Jan 1 00:25:04:260 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last 300 seconds input rate: 0 packets/sec, 0 bytes/sec in view system failed to be matched.
%Jan 1 00:25:04:327 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Last 300 seconds output rate: 0 packets/sec, 0 bytes/sec in view system failed to be matched.
%Jan 1 00:25:04:344 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command Input: 0 packets, 0 bytes in view system failed to be matched.
%Jan 1 00:25:04:934 2011 UNIS CFGMAN/5/CFGMAN_EXIT_FROM_CONFIGURE: -Line=con0-IPAddr=**-User=**; Exit from the system view or a feature view to the user view.
%Jan 1 00:25:31:272 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis interface fge1/0/53
%Jan 1 00:25:46:253 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis interface fge1/0/54
%Jan 1 00:26:37:368 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis interface fge1/0/54
%Jan 1 00:29:57:482 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command interface fge1/0/53 in view shell failed to be matched.
%Jan 1 00:30:53:890 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is quit
%Jan 1 00:30:53:894 2011 UNIS SHELL/5/SHELL_LOGOUT: Console logged out from con0.
%Jan 1 00:30:54:841 2011 UNIS SHELL/5/SHELL_LOGIN: Console logged in from con0.
%Jan 1 00:30:58:314 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is system
%Jan 1 00:31:20:438 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is interface fge1/0/53
%Jan 1 00:31:32:770 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is undo stp enable
%Jan 1 00:31:35:066 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is quit
%Jan 1 00:31:38:838 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is interface fge1/0/53
%Jan 1 00:31:48:720 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is quit
%Jan 1 00:31:51:665 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is interface fge1/0/54
%Jan 1 00:31:57:585 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is undo stp enable
%Jan 1 00:32:00:318 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is quit
%Jan 1 00:32:05:566 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis stp
%Jan 1 00:33:15:096 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is quit
%Jan 1 00:33:15:097 2011 UNIS CFGMAN/5/CFGMAN_EXIT_FROM_CONFIGURE: -Line=con0-IPAddr=**-User=**; Exit from the system view or a feature view to the user view.
%Jan 1 00:34:03:173 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis transceiver alarm interface fge1/0/53
%Jan 1 00:34:07:063 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis transceiver alarm interface fge1/0/54
%Jan 1 00:35:18:214 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis version
%Jan 1 00:36:07:370 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command dis logfile in view shell failed to be matched.
%Jan 1 00:36:46:858 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command dis logfile log in view shell failed to be matched.
%Jan 1 00:37:20:444 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis device
%Jan 1 00:37:51:134 2011 UNIS SHELL/6/SHELL_CMD: -Line=con0-IPAddr=**-User=**; Command is dis logbuffer
%Jan 1 00:43:34:763 2011 UNIS SHELL/4/SHELL_CMD_MATCHFAIL: -User=**-IPAddr=**; Command dis logfile log in view shell failed to be matched.
测试机器版本
UNIS Uniware Software, Version 7.1.070, Release 7753P05
Copyright (c) 2015-2022 Unisyue Technologies Co., Ltd.
UNIS S6600XP-54XG-EI-G uptime is 0 weeks, 0 days, 2 hours, 57 minutes
Last reboot reason : Cold reboot
Boot image: flash:/S6600XPG-UNW710-BOOT-R7753P05.bin
Boot image version: 7.1.070, Release 7753P05
Compiled Dec 27 2022 11:00:00
System image: flash:/S6600XPG-UNW710-SYSTEM-R7753P05.bin
System image version: 7.1.070, Release 7753P05