一、客户端
A.在redhat或者centos系统里安装
1、安装dell的yum源
wget -O - http://linux.dell.com/repo/hardware/latest/bootstrap.cgi |bash
2、安装omsa
yum install srvadmin-all
ps:出现某些包下载超时时,再次执行上面命令,直到全部下载安装完成.
3、做软连接
1.ln -s/opt/dell/srvadmin/sbin/omreport /usr/bin/omreport
2.ln -s/opt/dell/srvadmin/sbin/omconfig /usr/bin/omconfig
4、关闭web模式(仅允许运行cli)
echo "/usr/bin/omconfig systemwebserver action=stop">>/opt/dell/srvadmin/sbin/srvadmin-services.sh
5、启动omsa
/opt/dell/srvadmin/sbin/srvadmin-services.sh start
Ps:如果启动报以下错误,需要安装openipmi服务 yum -y install OpenIPMI
报错信息:
[root@xxxxx/]# /opt/dell/srvadmin/sbin/srvadmin-services.sh start
StartingSystems Management Device Drivers:
Startingdell_rbu: Already started [ OK ]
Startingipmi driver: [FAILED]
StartingSystems Management Device Drivers:
Startingdell_rbu: Already started [ OK ]
Startingipmi driver: [FAILED]
DSM SAShared Services is already started
StartingDSM SA Connection Service: [ OK ]
DSM SAConnection Service stopped successfully.
Ps:如果启动报以下错误,原因是 dell smbios 的版本不够,没读取出机器的识别码
升级一下,即可。 yum update python-smbios �Cy
报错信息:
Starting Systems Management Data Engine:
Failed to start because system is not supported
dsm_om_shrsvc: DSM SA Shared Services cannot start on an unsupportedsystem. See the Dell Systems Software Support Matrix for a list of supported systems.
6、检查omsa启动状态
/opt/dell/srvadmin/sbin/srvadmin-services.sh status
dell_rbu(module) is running
ipmidriver is running
dsm_sa_datamgrd(pid 40936 40874) is running
dsm_sa_eventmgrd(pid 40950) is running
dsm_sa_snmpd(pid 40973) is running
dsm_om_shrsvcd(pid 41018) is running
dsm_om_connsvcdis stopped
Error!DSM SA Connection Service is already stopped.
Ps:最后两行错误可以忽略
7、把omsa加入到开机启动里
echo "/opt/dell/srvadmin/sbin/srvadmin-services.shstart">>/etc/rc.local
以上是在centos或者redhat系统里安装omsa。
B.ubuntu下安装
1、增加源
echo 'debhttp://linux.dell.com/repo/community/ubuntu precise openmanage' | sudo tee -a/etc/apt/sources.list.d/linux.dell.com.sources.list
2、检测与增加key
1.gpg --keyserverpool.sks-keyservers.net --recv-key 1285491434D8786F
2.gpg -a --export1285491434D8786F | sudo apt-key add -
3、更新源
apt-get update -y
4、安装omsa
apt-get install srvadmin-all -y
5、做软连接
1.ln -s/opt/dell/srvadmin/sbin/omreport /usr/bin/omreport
2.ln -s/opt/dell/srvadmin/sbin/omconfig /usr/bin/omconfig
6、启动cli模式omsa
service dataeng start
C.zabbix客户端的配置
1、在zabbix_agentd.conf里添加以下配置,添加到最后
#follow is monitor hardware
UserParameter=hardware_battery,omreport chassis batteries|awk'/^Status/{if($NF=="Ok") {print 1} else {print 0}}'
UserParameter=hardware_cpu_model,awk -v hardware_cpu_crontol=`sudoomreport chassis biossetup|awk '/CState/{if($NF=="Enabled") {print 0} else {print 1}}'` -v hardware_cpu_c1=`sudo omreportchassis biossetup|awk '/C1[-|E]/{if($NF=="Enabled") {print 0} else{print 1}}'` 'BEGIN{if(hardware_cpu_crontol==0 && hardware_cpu_c1==0){print 0} else {print 1}}'
UserParameter=hardware_fan_health,awk -vhardware_fan_number=`omreport chassis fans|grep -c "^Index"` -vhardware_fan=`omreport chassis fans|awk '/^Status/{if($NF=="Ok")count+=1}END{print count}'` 'BEGIN{if(hardware_fan_number==hardware_fan) {print1} else {print 0}}'
UserParameter=hardware_memory_health,awk -vhardware_memory=`omreport chassis memory|awk '/^Health/{print $NF}'`'BEGIN{if(hardware_memory=="Ok") {print 1} else {print 0}}'
UserParameter=hardware_nic_health,awk -vhardware_nic_number=`omreport chassis nics |grep -c "Interface Name"`-v hardware_nic=`omreport chassis nics |awk '/^Connection Status/{print$NF}'|wc -l` 'BEGIN{if(hardware_nic_number==hardware_nic) {print 1} else {print0}}'
UserParameter=hardware_cpu,omreport chassis processors|awk'/^Health/{if($NF=="Ok") {print 1} else {print 0}}'
UserParameter=hardware_power_health,awk -vhardware_power_number=`omreport chassis pwrsupplies|grep -c "Index"`-v hardware_power=`omreport chassis pwrsupplies|awk'/^Status/{if($NF=="Ok") count+=1}END{print count}'`'BEGIN{if(hardware_power_number==hardware_power) {print 1} else {print 0}}'
UserParameter=hardware_temp,omreport chassis temps|awk'/^Status/{if($NF=="Ok") {print 1} else {print 0}}'|head -n 1
UserParameter=hardware_physics_health,awk -vhardware_physics_disk_number=`omreport storage pdisk controller=0|grep -c"^ID"` -v hardware_physics_disk=`omreport storage pdiskcontroller=0|awk '/^Status/{if($NF=="Ok") count+=1}END{print count}'`'BEGIN{if(hardware_physics_disk_number==hardware_physics_disk) {print 1} else{print 0}}'
UserParameter=hardware_virtual_health,awk -v hardware_virtual_disk_number=`omreportstorage vdisk controller=0|grep -c "^ID"` -vhardware_virtual_disk=`omreport storage vdisk controller=0|awk'/^Status/{if($NF=="Ok") count+=1}END{print count}'`'BEGIN{if(hardware_virtual_disk_number==hardware_virtual_disk) {print 1} else{print 0}}'
2、重启zabbix_agentd服务
/etc/init.d/zabbix_agentd restart
3、测试获取数据:出现值为正常
[root@xxxxxx]# ../bin/zabbix_get -s 127.0.0.1 -k "hardware_virtual_health"
1
二、服务端
1、模板导入
把TemplateHardware Monitor模版导入到zabbix里
2、主机关联模板
把需要监控的硬件服务器关联此模板即可
3、监控图例