cisco 6500 业务版重启

Jun 24 18:56:09.269: %PM_SCP-1-LCP_FW_ERR: System resetting module 3 to recover from error: Linecard received system exception. Errcode = 

        2709000001

Jun 24 18:56:09.269: %OIR-3-PWRCYCLE: Card in module 3, is being power-cycled 'Off (Module Reset due to exception or user request)'

Jun 24 18:56:09.285: %OSPF-5-ADJCHG: Process 10, Nbr 10.16.2.241 on TenGigabitEthernet3/5 from FULL to DOWN, Neighbor Down: Interface down or detached

Jun 24 18:56:09.285: %OSPF-5-ADJCHG: Process 10, Nbr 10.9.15.94 on TenGigabitEthernet3/7 from FULL to DOWN, Neighbor Down: Interface down or detached

Jun 24 18:56:09.321: %OSPF-5-ADJCHG: Process 10, Nbr 11.7.34.21 on Vlan15 from FULL to DOWN, Neighbor Down: Interface down or detached

Jun 24 18:56:09.501: %C6KPWR-4-DISABLED: power to module in slot 3 set Off (Module Reset due to exception or user request)

*Mar  1 00:00:12.315: ppc_lc_ibc_subsys_init: ETSEC IBC INIT DONE


Firmware compiled 24-May-12 21:43 by integ Build [101]

Jun 24 18:57:28.937: %SYS-DFC3-5-RESTART: System restarted --

Cisco IOS Software, c4lc Software (c4lc-SP-M), Version 15.0(1)SY2, RELEASE SOFTWARE (fc4)

Technical Support: http://www.cisco.com/techsupport

Copyright (c) 1986-2012 by Cisco Systems, Inc.

Compiled Tue 10-Jul-12 13:04 by prod_rel_team

Jun 24 18:57:28.953: DFC3: Currently running ROMMON from S (Gold) region

Jun 24 18:57:44.573: %DIAG-6-RUN_MINIMUM: Module 3: Running Minimal Diagnostics...

Jun 24 18:58:16.229: %DIAG-6-DIAG_OK: Module 3: Passed Online Diagnostics

Jun 24 18:58:17.453: %OIR-6-SP_INSCARD: Card inserted in slot 3, interfaces are now online

Jun 24 18:59:08.369: %OSPF-5-ADJCHG: Process 10, Nbr 10.9.15.94 on TenGigabitEthernet3/7 from LOADING to FULL, Loading Done

Jun 24 18:59:13.225: %OSPF-5-ADJCHG: Process 10, Nbr 10.16.2.241 on TenGigabitEthernet3/5 from LOADING to FULL, Loading Done

Jun 24 18:59:16.077: %OSPF-5-ADJCHG: Process 10, Nbr 11.7.34.21 on Vlan15 from LOADING to FULL, Loading Done



C6509-A#show power            

system power redundancy mode = redundant

system power total =     5771.64 Watts (137.42 Amps @ 42V)

system power used =      3433.08 Watts (81.74 Amps @ 42V)

system power available = 2338.56 Watts (55.68 Amps @ 42V)

                        Power-Capacity PS-Fan Output Oper

PS   Type               Watts   A @42V Status Status State

---- ------------------ ------- ------ ------ ------ -----

1    WS-CAC-6000W       5771.64 137.42 OK     OK     on 

2    WS-CAC-6000W       5771.64 137.42 OK     OK     on 

                        Pwr-Allocated  Oper

Fan  Type               Watts   A @42V State

---- ------------------ ------- ------ -----

1    WS-C6509-E-FAN      210.00  5.00  OK


                        Pwr-Requested  Pwr-Allocated  Admin Oper

Slot Card-Type          Watts   A @42V Watts   A @42V State State

---- ------------------ ------- ------ ------- ------ ----- -----

1    WS-X6908-10G        588.00 14.00   588.00 14.00  on    on

2    WS-X6908-10G        588.00 14.00   588.00 14.00  on    on

3    WS-X6908-10G        588.00 14.00   588.00 14.00  on    on

4    WS-X6908-10G        588.00 14.00   588.00 14.00  on    on

5    VS-SUP2T-10G        435.54 10.37   435.54 10.37  on    on

6    (Redundant Sup)       -     -      435.54 10.37  -     -

system auxiliary power mode = off

system auxiliary power redundancy operationally = non-redundant

system primary connector power limit =   10920.00 Watts (260.00 Amps @ 42V)

system auxiliary connector power limit = 10500.00 Watts (250.00 Amps @ 42V)

system primary power used =              3433.08 Watts (81.74 Amps @ 42V)

system auxiliary power used =            0 Watt