一个由4台路由器连接的帧中继点到点网络的操作实例

         此实验过程是使用Boson NetSim for CCNP version 6.0 BETA 1软件下做的。其中使用一台C3640和三台C2501路由器。
 
一个由4台路由器连接的帧中继点到点网络的操作实例
 
 
 
如果要每个 DTE 端子接口与对方的每个子接口通信必须进行 route rip
 
R1 R3640
-----------------------------------------------------------------------------------------------------------------------
Press Enter to Start
 
 
Router>
Router>
Router>
Router>enable
Router#show version
 
Boson Operating Simulation Software
BOSS (tm) C3600 Software (C3600-Enterprise), Version 12.1, RELEASE SOFTWARE
Copyright (c) 1998-2003 by Boson Software, Inc.
 
BOSS ROM: System Bootstrap, Version 12.2, RELEASE SOFTWARE
Router Uptime Is 0 days, 0 hours, 2 minutes
System restarted by power-on
System image file is ""flash:c3600-enterprise.12.1.boss"", booted via flash
Boson 3600 (BOSS) processor (revision 5.0)
1 Ethernet/IEEE 802.3 interface(s)
1 Fast Ethernet/IEEE 802.3 interface(s)
1 Serial network interface(s)
3 ISDN Basic Rate interface(s)
32K bytes of simulated non-volatile configuration memory.
8192K bytes of simulated System flash (Read/Write)
 
 
Configuration register is 0X2102
 
Router#
Router#
Router#
Router#configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
Router(config)#hostname R1
R1(config)#
R1(config)#
R1(config)#interface serial 0/0
R1(config-if)#no shutdown
%LINK-3-UPDOWN: Interface Serial0/0, changed state to up
%LINK-3-UPDOWN: Interface Serial0/0, changed state to down
%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial0/0, changed state to down
R1(config-if)#no ip address
R1(config-if)#encapsulation frame-relay
R1(config-if)#
R1(config-if)#interface serial 0/0.2 point-to-point
R1(config-subif)#ip address 10.1.1.1 255.255.255.252
R1(config-subif)#bandwidth 64
R1(config-subif)#frame-relay interface-dlci 102
R1(config-subif)#
R1(config-subif)#
R1(config-subif)# interface serial 0/0.3 point-to-point
R1(config-subif)#ip address 10.1.1.5 255.255.255.252
R1(config-subif)#bandwidth 64
R1(config-subif)#frame-relay interface-dlci 103
R1(config-subif)#
R1(config-subif)#interface serial 0/0.4 point-to-point
R1(config-subif)#ip address 10.1.1.8 255.255.255.252
R1(config-subif)#bandwidth 64
R1(config-subif)#frame-relay interface-dlci 104
R1(config-subif)#
%LINK-3-UPDOWN: Interface Serial0/0, changed state to up
%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial0/0, changed state to up
21:49:39: %FR-5-DLCICHANGE: Interface Serial0/0.2 - DLCI 102 state changed to ACTIVE
21:49:39: %FR-5-DLCICHANGE: Interface Serial0/0.3 - DLCI 103 state changed to ACTIVE
21:49:39: %FR-5-DLCICHANGE: Interface Serial0/0.4 - DLCI 104 state changed to ACTIVE
R1(config-subif)#end
R1#
R1#
R1#show frame-relay lmi
show frame-relay lmi
 
LMI Statistics for interface Serial0/0 (Frame Relay DTE) LMI TYPE = CISCO
Invalid Unnumbered info 0             Invalid Prot Disc 0
Invalid dummy Call Ref 0              Invalid Msg Type 0
Invalid Status Message 0              Invalid Lock Shift 0
Invalid Information ID 0              Invalid Report IE Len 0
Invalid Report Request 0              Invalid Keep IE Len 0
Num Status Enq. Sent 160              Num Status msgs Rcvd 137
Num Update Status Rcvd 0              Num Status Timeouts 13
 
 
R1#
R1#
R1#show interface serial 0/0
Serial0/0 is up, line protocol is up
  Hardware is HD64570
  MTU 1500 bytes, BW 1544 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
  LMI enq sent  1472, LMI stat recvd 1472, LMI upd recvd 0, DTE LMI up
  LMI enq recvd 0, LMI stat sent  0, LMI upd sent  0
  LMI DLCI 0  LMI type is CISCO  frame relay DTE
  FR SVC disabled, LAPF state down
  Broadcast queue 0/64, broadcasts sent/dropped 0/0, interface broadcasts 300
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of show interface counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 1000 bits/sec, 2 packets/sec
  5 minute output rate 1000 bits/sec, 2 packets/sec
     0 packets input, 0 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     0 input packets with dribble condition detected
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out
 
R1#
R1#
R1#show interface serial 0/0.2
Serial0/0.2.2 is up, line protocol is up
  Internet address is 10.1.1.1/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R1#
R1#
R1#show interface serial 0/0.3
Serial0/0.3.3 is up, line protocol is up
  Internet address is 10.1.1.5/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R1#
R1#
R1#show interface serial 0/0.4
Serial0/0.4.4 is up, line protocol is up
  Internet address is 10.1.1.8/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R1#
R1#
R1#show frame-relay map
Serial0/0.2 (up): point-to-point dlci, dlci 102(0x66,0x1860), broadcast
        status defined, active
Serial0/0.3 (up): point-to-point dlci, dlci 103(0x66,0x1860), broadcast
        status defined, active
Serial0/0.4 (up): point-to-point dlci, dlci 104(0x66,0x1860), broadcast
        status defined, active
 
R1#
R1#
R1#show frame-relay pvc
PVC Statistics for interface Serial0/0 (Frame Relay DTE)
 
DLCI = 102, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0.2
 
input pkts 88                output pkts 57               in bytes 14504
out bytes 6037               dropped pkts 80              in FECN pkts 112 
in BECN pkts 70              out FECN pkts 110            out BECN pkts 78   
in DE pkts 87                out DE pkts 28  
out bcast pkts 119           out bcast bytes 13809
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
PVC Statistics for interface Serial0/0 (Frame Relay DTE)
 
DLCI = 103, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0.3
 
input pkts 99                output pkts 23               in bytes 1595
out bytes 8099               dropped pkts 117             in FECN pkts 55  
in BECN pkts 68              out FECN pkts 60             out BECN pkts 86  
in DE pkts 93                out DE pkts 9  
out bcast pkts 58            out bcast bytes 7245
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
PVC Statistics for interface Serial0/0 (Frame Relay DTE)
 
DLCI = 104, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0.4
 
input pkts 82                output pkts 105              in bytes 11271
out bytes 4828               dropped pkts 77              in FECN pkts 120 
in BECN pkts 47              out FECN pkts 91             out BECN pkts 78  
in DE pkts 54                out DE pkts 8  
out bcast pkts 29            out bcast bytes 3340
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
 
 
R1#
R1#
 
R2 R2501
-----------------------------------------------------------------------------------------------------------------------
Press Enter to Start
 
 
Router>
Router>enable
Router#show version
 
Boson Operating Simulation Software
BOSS (tm) C2500 Software (C2500-Enterprise), Version 12.1, RELEASE SOFTWARE
Copyright (c) 1998-2003 by Boson Software, Inc.
 
BOSS ROM: System Bootstrap, Version 12.2, RELEASE SOFTWARE
Router Uptime Is 0 days, 0 hours, 0 minutes
System restarted by power-on
System image file is ""flash:c2500-enterprise.12.1.boss"", booted via flash
Boson 2500 (BOSS) processor (revision 5.0)
1 Ethernet/IEEE 802.3 interface(s)
2 Serial network interface(s)
3 ISDN Basic Rate interface(s)
32K bytes of simulated non-volatile configuration memory.
8192K bytes of simulated System flash (Read/Write)
 
 
Configuration register is 0X2102
 
Router#
Router#
Router#configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
Router(config)#hostname R2
R2(config)#
R2(config)#
R2(config)#interface serial 0
R2(config-if)#no shutdown
%LINK-3-UPDOWN: Interface Serial0, changed state to up
R2(config-if)#no ip address
%LINK-3-UPDOWN: Interface Serial0, changed state to down
%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial0, changed state to down
R2(config-if)#encapsulation frame-relay
R2(config-if)#
R2(config-if)#
%LINK-3-UPDOWN: Interface Serial0, changed state to up
%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial0, changed state to up
R2(config-if)#interface serial 0.2 point-to-point
R2(config-subif)#ip address 10.1.1.2 255.255.255.252
R2(config-subif)#bandwidth 64
R2(config-subif)#frame-relay interface-dlci 201
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.2 - DLCI 201 state changed to ACTIVE
R2(config-subif)#
R2(config-subif)#interface serial 0.3 point-to-point
R2(config-subif)#ip address 10.1.1.11 255.255.255.252
R2(config-subif)#bandwidth 64
R2(config-subif)#frame-relay interface-dlci 203
R2(config-subif)#
R2(config-subif)#
R2(config-subif)#interface serial 0.4 point-to-point
R2(config-subif)#ip address 10.1.1.14 255.255.255.252
R2(config-subif)#bandwidth 64
R2(config-subif)#frame-relay interface-dlci 204
R2(config-subif)#
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.3 - DLCI 203 state changed to ACTIVE
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.4 - DLCI 204 state changed to ACTIVE
R2(config-subif)#end
R2#
R2#
R2#show frame-relay lmi
show frame-relay lmi
 
LMI Statistics for interface Serial0 (Frame Relay DTE) LMI TYPE = CISCO
Invalid Unnumbered info 0             Invalid Prot Disc 0
Invalid dummy Call Ref 0              Invalid Msg Type 0
Invalid Status Message 0              Invalid Lock Shift 0
Invalid Information ID 0              Invalid Report IE Len 0
Invalid Report Request 0              Invalid Keep IE Len 0
Num Status Enq. Sent 160              Num Status msgs Rcvd 137
Num Update Status Rcvd 0              Num Status Timeouts 13
 
 
R2#
R2#
R2#show interface serial 0
Serial0 is up, line protocol is up
  Hardware is HD64570
  MTU 1500 bytes, BW 1544 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
  LMI enq sent  1472, LMI stat recvd 1472, LMI upd recvd 0, DTE LMI up
  LMI enq recvd 0, LMI stat sent  0, LMI upd sent  0
  LMI DLCI 0  LMI type is CISCO  frame relay DTE
  FR SVC disabled, LAPF state down
  Broadcast queue 0/64, broadcasts sent/dropped 0/0, interface broadcasts 300
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of show interface counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 1000 bits/sec, 2 packets/sec
  5 minute output rate 1000 bits/sec, 2 packets/sec
     0 packets input, 0 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     0 input packets with dribble condition detected
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out
 
R2#show interface serial 0.2
Serial0.2.2 is up, line protocol is up
  Internet address is 10.1.1.2/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R2#
R2#
R2#show interface serial 0.3
Serial0.3.3 is up, line protocol is up
  Internet address is 10.1.1.11/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R2#
R2#
R2#show interface serial 0.4
Serial0.4.4 is up, line protocol is up
  Internet address is 10.1.1.14/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R2#
R2#
R2#show frame-relay map
Serial0.2 (up): point-to-point dlci, dlci 201(0x66,0x1860), broadcast
        status defined, active
Serial0.3 (up): point-to-point dlci, dlci 203(0x66,0x1860), broadcast
        status defined, active
Serial0.4 (up): point-to-point dlci, dlci 204(0x66,0x1860), broadcast
        status defined, active
 
R2#
R2#
R2#show frame-relay pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 201, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.2
 
input pkts 104               output pkts 116              in bytes 9842
out bytes 7840               dropped pkts 82              in FECN pkts 33  
in BECN pkts 62              out FECN pkts 61             out BECN pkts 97  
in DE pkts 105               out DE pkts 112 
out bcast pkts 93            out bcast bytes 3557
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 203, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.3
 
input pkts 66                output pkts 49               in bytes 1238
out bytes 10914              dropped pkts 95              in FECN pkts 24  
in BECN pkts 89              out FECN pkts 99             out BECN pkts 13  
in DE pkts 36                out DE pkts 84  
out bcast pkts 114           out bcast bytes 10318
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 204, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.4
 
input pkts 54                output pkts 116              in bytes 5718
out bytes 5362               dropped pkts 110             in FECN pkts 68  
in BECN pkts 107             out FECN pkts 75             out BECN pkts 85  
in DE pkts 25                out DE pkts 85  
out bcast pkts 111           out bcast bytes 11746
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
 
 
R2#
R2#
 
R3 R2501
-----------------------------------------------------------------------------------------------------------------------
Press Enter to Start
 
 
Router>
Router>
Router>enable
Router#show version
 
Boson Operating Simulation Software
BOSS (tm) C2500 Software (C2500-Enterprise), Version 12.1, RELEASE SOFTWARE
Copyright (c) 1998-2003 by Boson Software, Inc.
 
BOSS ROM: System Bootstrap, Version 12.2, RELEASE SOFTWARE
Router Uptime Is 0 days, 0 hours, 14 minutes
System restarted by power-on
System image file is ""flash:c2500-enterprise.12.1.boss"", booted via flash
Boson 2500 (BOSS) processor (revision 5.0)
1 Ethernet/IEEE 802.3 interface(s)
2 Serial network interface(s)
3 ISDN Basic Rate interface(s)
32K bytes of simulated non-volatile configuration memory.
8192K bytes of simulated System flash (Read/Write)
 
 
Configuration register is 0X2102
 
Router#
Router#
Router#configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
Router(config)#hostname R3
R3(config)#
R3(config)#
R3(config)#interface serial 0
R3(config-if)#no shutdown
%LINK-3-UPDOWN: Interface Serial0, changed state to up
R3(config-if)#no ip address
%LINK-3-UPDOWN: Interface Serial0, changed state to down
%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial0, changed state to down
R3(config-if)#encapsulation frame-relay
%LINK-3-UPDOWN: Interface Serial0, changed state to up
%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial0, changed state to up
R3(config-if)#
R3(config-if)#interface serial 0.2 point-to-point
R3(config-subif)#ip address 10.1.1.6 255.255.255.252
R3(config-subif)#bandwidth 64
R3(config-subif)#frame-relay interface-dlci 301
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.2 - DLCI 301 state changed to ACTIVE
R3(config-subif)#
R3(config-subif)#
R3(config-subif)#interface serial 0.3 point-to-point
R3(config-subif)#ip address 10.1.1.12 255.255.255.252
R3(config-subif)#bandwidth 64
R3(config-subif)#frame-relay interface-dlci 302
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.3 - DLCI 302 state changed to ACTIVE
R3(config-subif)#
R3(config-subif)#
R3(config-subif)#interface serial 0.4 point-to-point
R3(config-subif)#ip address 10.1.1.17 255.255.255.252
R3(config-subif)#bandwidth 64
R3(config-subif)#frame-relay interface-dlci 304
R3(config-subif)#
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.4 - DLCI 304 state changed to ACTIVE
R3(config-subif)#end
R3#
R3#
R3#show frame-relay lmi
show frame-relay lmi
 
LMI Statistics for interface Serial0 (Frame Relay DTE) LMI TYPE = CISCO
Invalid Unnumbered info 0             Invalid Prot Disc 0
Invalid dummy Call Ref 0              Invalid Msg Type 0
Invalid Status Message 0              Invalid Lock Shift 0
Invalid Information ID 0              Invalid Report IE Len 0
Invalid Report Request 0              Invalid Keep IE Len 0
Num Status Enq. Sent 160              Num Status msgs Rcvd 137
Num Update Status Rcvd 0              Num Status Timeouts 13
 
 
R3#
R3#
R3#show interface serial 0
Serial0 is up, line protocol is up
  Hardware is HD64570
  MTU 1500 bytes, BW 1544 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
  LMI enq sent  1472, LMI stat recvd 1472, LMI upd recvd 0, DTE LMI up
  LMI enq recvd 0, LMI stat sent  0, LMI upd sent  0
  LMI DLCI 0  LMI type is CISCO  frame relay DTE
  FR SVC disabled, LAPF state down
  Broadcast queue 0/64, broadcasts sent/dropped 0/0, interface broadcasts 300
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of show interface counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 1000 bits/sec, 2 packets/sec
  5 minute output rate 1000 bits/sec, 2 packets/sec
     0 packets input, 0 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     0 input packets with dribble condition detected
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out
 
R3#
R3#
R3#show interface serial 0.2
Serial0.2.2 is up, line protocol is up
  Internet address is 10.1.1.6/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R3#
R3#
R3#show interface serial 0.3
Serial0.3.3 is up, line protocol is up
  Internet address is 10.1.1.12/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R3#
R3#
R3#show interface serial 0.4
Serial0.4.4 is up, line protocol is up
  Internet address is 10.1.1.17/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R3#
R3#
R3#show frame-relay map
Serial0.3 (up): point-to-point dlci, dlci 302(0x66,0x1860), broadcast
        status defined, active
Serial0.2 (up): point-to-point dlci, dlci 301(0x66,0x1860), broadcast
        status defined, active
Serial0.4 (up): point-to-point dlci, dlci 304(0x66,0x1860), broadcast
        status defined, active
 
R3#
R3#
R3#show frame-relay pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 301, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.2
 
input pkts 85                output pkts 78               in bytes 1056
out bytes 7303               dropped pkts 117             in FECN pkts 99  
in BECN pkts 90              out FECN pkts 117            out BECN pkts 37  
in DE pkts 71                out DE pkts 120 
out bcast pkts 92            out bcast bytes 13807
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 302, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.3
 
input pkts 49                output pkts 37               in bytes 12636
out bytes 5284               dropped pkts 119             in FECN pkts 47  
in BECN pkts 59              out FECN pkts 78             out BECN pkts 54  
in DE pkts 7                out DE pkts 28  
out bcast pkts 29            out bcast bytes 2784
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 304, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.4
 
input pkts 37                output pkts 89               in bytes 12778
out bytes 14840              dropped pkts 72              in FECN pkts 102 
in BECN pkts 100             out FECN pkts 18             out BECN pkts 27  
in DE pkts 33                out DE pkts 14  
out bcast pkts 71            out bcast bytes 12838
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
 
 
R3#
R3#
 
R4 R2501
-----------------------------------------------------------------------------------------------------------------------
Press Enter to Start
 
 
Router>
Router>
Router>enable
Router#show version
 
Boson Operating Simulation Software
BOSS (tm) C2500 Software (C2500-Enterprise), Version 12.1, RELEASE SOFTWARE
Copyright (c) 1998-2003 by Boson Software, Inc.
 
BOSS ROM: System Bootstrap, Version 12.2, RELEASE SOFTWARE
Router Uptime Is 0 days, 0 hours, 18 minutes
System restarted by power-on
System image file is ""flash:c2500-enterprise.12.1.boss"", booted via flash
Boson 2500 (BOSS) processor (revision 5.0)
1 Ethernet/IEEE 802.3 interface(s)
2 Serial network interface(s)
3 ISDN Basic Rate interface(s)
32K bytes of simulated non-volatile configuration memory.
8192K bytes of simulated System flash (Read/Write)
 
 
Configuration register is 0X2102
 
Router#
Router#
Router#configure terminal
Enter configuration commands, one per line.  End with CNTL/Z.
Router(config)#hostname R4
R4(config)#
R4(config)#
R4(config)#interface serial 0
R4(config-if)#no shutdown
%LINK-3-UPDOWN: Interface Serial0, changed state to up
R4(config-if)#no ip address
%LINK-3-UPDOWN: Interface Serial0, changed state to down
%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial0, changed state to down
R4(config-if)#encapsulation frame-relay
%LINK-3-UPDOWN: Interface Serial0, changed state to up
%LINEPROTO-5-UPDOWN: Line protocol on Interface Serial0, changed state to up
R4(config-if)#
R4(config-if)#
R4(config-if)#interface serial 0.2 point-to-point
R4(config-subif)#ip address 10.1.1.9 255.255.255.252
R4(config-subif)#bandwidth 64
R4(config-subif)#frame-relay interface-dlci 401
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.2 - DLCI 401 state changed to ACTIVE
R4(config-subif)#
R4(config-subif)#
R4(config-subif)#interface serial 0.3 point-to-point
R4(config-subif)#ip address 10.1.1.15 255.255.255.252
R4(config-subif)#bandwidth 64
R4(config-subif)#frame-relay interface-dlci 402
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.3 - DLCI 402 state changed to ACTIVE
R4(config-subif)#
R4(config-subif)#
R4(config-subif)#interface serial 0.4 point-to-point
R4(config-subif)#ip address 10.1.1.18 255.255.255.252
R4(config-subif)#bandwidth 64
R4(config-subif)#frame-relay interface-dlci 403
21:49:39: %FR-5-DLCICHANGE: Interface Serial0.4 - DLCI 403 state changed to ACTIVE
R4(config-subif)#
R4(config-subif)#
R4(config-subif)#end
R4#
R4#
R4#show frame-relay lmi
show frame-relay lmi
 
LMI Statistics for interface Serial0 (Frame Relay DTE) LMI TYPE = CISCO
Invalid Unnumbered info 0             Invalid Prot Disc 0
Invalid dummy Call Ref 0              Invalid Msg Type 0
Invalid Status Message 0              Invalid Lock Shift 0
Invalid Information ID 0              Invalid Report IE Len 0
Invalid Report Request 0              Invalid Keep IE Len 0
Num Status Enq. Sent 160              Num Status msgs Rcvd 137
Num Update Status Rcvd 0              Num Status Timeouts 13
 
 
R4#
R4#
R4#show interface serial 0
Serial0 is up, line protocol is up
  Hardware is HD64570
  MTU 1500 bytes, BW 1544 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
  LMI enq sent  1472, LMI stat recvd 1472, LMI upd recvd 0, DTE LMI up
  LMI enq recvd 0, LMI stat sent  0, LMI upd sent  0
  LMI DLCI 0  LMI type is CISCO  frame relay DTE
  FR SVC disabled, LAPF state down
  Broadcast queue 0/64, broadcasts sent/dropped 0/0, interface broadcasts 300
  Last input 00:00:00, output 00:00:00, output hang never
  Last clearing of show interface counters never
  Queueing strategy: fifo
  Output queue 0/40, 0 drops; input queue 0/75, 0 drops
  5 minute input rate 1000 bits/sec, 2 packets/sec
  5 minute output rate 1000 bits/sec, 2 packets/sec
     0 packets input, 0 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     0 input packets with dribble condition detected
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out
 
R4#
R4#
R4#show interface serial 0.2
Serial0.2.2 is up, line protocol is up
  Internet address is 10.1.1.9/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R4#
R4#
R4#show interface serial 0.2
Serial0.2.2 is up, line protocol is up
  Internet address is 10.1.1.9/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R4#
R4#
R4#show interface serial 0.3
Serial0.3.3 is up, line protocol is up
  Internet address is 10.1.1.15/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R4#
R4#
R4#show interface serial 0.4
Serial0.4.4 is up, line protocol is up
  Internet address is 10.1.1.18/30
  MTU 1500 bytes, BW 64 Kbit, DLY 1000 usec, rely 255/255, load 1/255
  Encapsulation FRAME-RELAY, loopback not set, keepalive set (10 sec)
 
R4#
R4#
R4#show frame-relay map
Serial0.4 (up): point-to-point dlci, dlci 403(0x66,0x1860), broadcast
        status defined, active
Serial0.3 (up): point-to-point dlci, dlci 402(0x66,0x1860), broadcast
        status defined, active
Serial0.2 (up): point-to-point dlci, dlci 401(0x66,0x1860), broadcast
        status defined, active
 
R4#
R4#
R4#show frame-relay pvc
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 401, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.2
 
input pkts 6                output pkts 88               in bytes 5436
out bytes 6109               dropped pkts 98              in FECN pkts 45  
in BECN pkts 56              out FECN pkts 87             out BECN pkts 79  
in DE pkts 40                out DE pkts 71  
out bcast pkts 10            out bcast bytes 935 
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 402, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.3
 
input pkts 72                output pkts 92               in bytes 14735
out bytes 7914               dropped pkts 111             in FECN pkts 64  
in BECN pkts 118             out FECN pkts 41             out BECN pkts 100 
in DE pkts 41                out DE pkts 67  
out bcast pkts 53            out bcast bytes 11503
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
PVC Statistics for interface Serial0 (Frame Relay DTE)
 
DLCI = 403, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0.4
 
input pkts 57                output pkts 108              in bytes 8549
out bytes 11623              dropped pkts 109             in FECN pkts 100 
in BECN pkts 9              out FECN pkts 47             out BECN pkts 81  
in DE pkts 98                out DE pkts 101 
out bcast pkts 5            out bcast bytes 6963
pvc create time 00:32:04, last time pvc status changed 00:32:05
 
 
 
R4#
R4#
R4#

本文出自 “龙的传人” 博客,谢绝转载!

你可能感兴趣的:(网络,职场,休闲,帧中继)