关于aix 小机内置磁带机清洗问题

察看磁带机多久没有被清洗:
1、执行脚本 # /usr/lpp/diagnostics/bin/utape
在下面的选项中 选择 " rmt0             U787F.001.DPM5ANM-P1-T10-L0-L0"

SCSI TAPE SERVICE AID                                                                            802331

Select the device.

Move cursor to the selection, then press Enter.

  rmt0             U787F.001.DPM5ANM-P1-T10-L0-L0
                                        LVD SCSI 4mm Tape Drive

再选择  "Display Time Since Drive Was Last Cleaned"

SCSI TAPE SERVICE AID                                                                            802332
FOR rmt0 IN LOCATION U787F.001.DPM5ANM-P1-T10-L0-L0

Move cursor to the selection, then press Enter.

  Display Time Since Drive Was Last Cleaned
  Copy Trace Table
  Display or Copy Log Sense Information

最后出现最后一次磁带清洗到现在的时间:
DISPLAY TIME SINCE THE DRIVE WAS LAST CLEANED                                                    802336
FOR rmt0 IN LOCATION U787F.001.DPM5ANM-P1-T10-L0-L0

Usage time since the drive was last cleaned: 38.75 hours.
Device rmt0 does NOT need cleaning at this time.

To continue, press Enter.

如何清洗磁带:
磁带机清洗问题

我们的磁带机一般用了2个月左右,它就会有个提示我们要清洗磁带的灯会闪,这时我一般把清洗磁带的盘放进去,过5分钟左右就好了

 