SBL-SCM-00018: Could not open connection to Siebel Gateway configuration store

Siebel Configuration Wizard Fails With Error, "SBL-SCM-00018: Could not open connection to Siebel Gateway configuration store" [ID 870263.1] 转到底部
修改时间:2013-3-6类型:PROBLEM状态:PUBLISHED优先级:3
注释 (0)

In this Document

  Symptoms
  Cause
  Solution


Applies to:

Siebel CRM - Version 8.0 [20405] to 8.2.2.2 SIA[23016] [Release V8]
Information in this document applies to any platform.
***Checked for relevance on 06-Mar-2013***


Symptoms


When Running the Siebel Server Configurator, It Fails Showing the Error: "SBL-SCM-00018: Could not open connection to Siebel Gateway configuration store"

Cause


There is an error with the DB parameters during the Gateway and Enterprise configuration.

The configurator cannot locate a login (because it cannot reach the DB), so the Server configurator fails to start

Solution


Steps to solve the issue:

- Run the Gateway configurator
- Delete the Enterprise configuration
- Run the Gateway configuration again
- Delete the Gateway server
- Create a new Gateway server, checking that the DB server and hostname are correct
- Create a new Enterprise, checking that the DB server and hostname are correct.
- Run the Siebel server configurator