B18. Alarm Messages-6&B19. View Customization-1

1054 Exasmoc controller was normally terminated %s(Exasmoc控制器正常停止%s) 控制器正常停止。检查历史消息和日志,并确认是否合理。
1055 Exasmoc controller was terminated with error %s (Exasmoc控制器故障停止%s) 控制器异常停止。检查历史消息和日志,并确认是否合理。
1060 Exasmoc controller was terminated with OPC error %s(Exasmoc控制器因OPC故障停止%s)。 控制器由于OPC故障而停止。检查OPC通信。
1399 VersionIdent: %s%s 显示SMOC版本号。
R3.06
1062 [%s] (%s) Invalid MV Set Point High Limit",([%s](%s)无效的MV设定高限。) MV设定高限不正确。确认设定高限。
1063 [%s] (%s) Invalid MV Set Point Low Limit([%s](%s)无效的MV设定低限。) MV设定低限不正确。确认设定低限。
1064 [%s] (%s) Invalid MV Set Point High or Low Limit([%s](%s)无效的MV设定高/低限。) MV设定高/低限不正确。确认设定高/低限。
1066 [CALC] (%s) Invalid CALC Input High or Low Limit ([CALC](%s)CALC输入高限或低限无效。) 计算输入高限或低限不正确。确认高/低限。
1067 [CALC] (%s) Invalid CALC Output High or Low Limit([CALC](%s)CALC输出高限或低限无效。) 计算输出高限或低限不正确。确认高/低限。
R4.01
1071 Exasmoc Version: %s (Exasmoc版本:%s) 显示Exasmoc修订号。
1072 Exasmoc Database is FULL (Exasmoc数据库已满)。 Exasmoc内部数据库没有空间。确认MV,POV,CV,...的数量是否超过最大值,请重新启动PC并逐个启动必要的控制器。联系产品支持。
1076 Cannot connect to ISS Server (无法连接到ISS服务器)。 不能连接到多个OPC服务器。确认所有OPC通信。
R4.02
1077 Invalid DCS Delay Time (DCS延迟时间无效)。 调度器的DCS延迟时间设置为大于控制周期。所以控制器不能启动。
R4.03
1078 Cannot authenticate to OPC Server (无法向OPC服务器进行身份验证)。 发生了OPC认证错误。

B19视图自定义

根据视图操作者(R4.02或更高版本)的具体需求,可以对每个Exasmoc视图进行自定义配置。每个视图可以根据用户角色分配选择要显示和操作的位号变量。
在以下示例中,每个用户可以通过将两个或多个控制器的任意位号变量(每个视图的概述/子概述/ MV / DV / POV / CV)组合在一起来组合视图(ViewA / ViewB / ViewC)。
自定义视图可以从基于角色构建器中进行配置。 视图的用户权限是在基于角色中定义的。

B18. Alarm Messages-6&B19. View Customization-1_第1张图片
Fig. 19.1 Customization of each view 图19.1每个视图的自定义

1054 Exasmoc controller was normally terminated %s The controller stopped normally. Check the historical messages and logs and confirm if it is reasonable.
1055 Exasmoc controller was terminated with error %s The controller stopped abnormally. Check the historical messages and logs and confirm if it is reasonable.
1060 Exasmoc controller was terminated with OPC error %s The controller stopped with OPC error. Check the OPC communication.
1399 VersionIdent: %s%s SMOC version number is displayed.
R3.06
1062 [%s] (%s) Invalid MV Set Point High Limit", MV Set Point High Limit is not correct. Confirm the Set Point High/Limit.
1063 [%s] (%s) Invalid MV Set Point Low Limit MV Set Point Low Limit is not correct. Confirm the Set Point Low Limit.
1064 [%s] (%s) Invalid MV Set Point High or Low Limit MV Set Point High or Low Limit is not correct. Confirm the Set Point High / Low Limit.
1066 [CALC] (%s) Invalid CALC Input High or Low Limit Calculation Input High or Low Limit is not correct. Confirm the High / Low Limit.
1067 [CALC] (%s) Invalid CALC Output High or Low Limit Calculation Output High or Low Limit is not correct. Confirm the High / Low Limit.
R4.01
1071 Exasmoc Version: %s Exasmoc revision number is shown.
1072 Exasmoc Database is FULL Exasmoc internal database area has no space. To confirm if the number of MV, POV, CV,… are over the maximum, reboot PC and start only the necessary controllers one by one. Contact to the Product Support.
1076 Cannot connect to ISS Server Cannot connect to Multiple OPC server. Confirm all the OPC communication.
R4.02
1077 Invalid DCS Delay Time DCS Delay time of the scheduler is set to be larger than the control period. So the controller cannot start.
R4.03
1078 Cannot authenticate to OPC Server The OPC authentication error occurred.

B19. View Customization

Each Exasmoc view configuration can be customized according to each user who operates the view (R4.02 or later). Each view can select tag variables to be displayed and operated according to the user’s role assigned to the view.
In the following example, each user can compose views (ViewA / ViewB / ViewC) by combining arbitrary tag variables (each view of Overview / Sub-overview /MV / DV / POV / CV) from those of two or more controllers.
The customized view is configurable from the role-base builder. The user authority of the view is defined from the role-base definition.