交换机断电后引起的config/bin文件的丢失和损坏

issues

The secure application files does not exist-flash:/secure.bin!

slove

  • 先使用tftp从其它同型号的交换机上下载bin文件备用
tftp 192.168.0.100 put flash:/s5110_52p_si-cmw520-r1108.bin
  • 进入异常交换机的EXTEND-BOOTWARE MENU
# step 1 EXTEND-BOOTWARE MENU
<4> File Control
<4> Delete File
delete all

# step 2 EXTEND-BOOTWARE MENU
<3> Enter Ethernet SubMenu
<5> Modify Ethernet Parameter
 Protocol (FTP or TFTP) :tftp 
Load File Name         :s5110_52p_si-cmw520-r1108.bin
                       :
Target File Name       :target
                       :
Server IP Address      :192.168.2.1 
Local IP Address       :192.168.2.2 
Gateway IP Address     :0.0.0.0 

# 配置tftp pc 为提示中的server ip

# step 3 
<1> Download Application Program To SDRAM And Run 
enter

# 此时交换机已正常运行
导入备份的config,或者重新config
导入启动镜像
tftp 192.168.0.2 get s5110_52p_si-cmw520-r1108.bin
save