最近 练习安装lync2013 在发布拓扑结构时遇到如下错误:
lync 错误: 已为不同的传输层安全性(TLS)目标找到类型为“McxInternal”且完全限定的域名(FQDN)为“lync.contoso.com”的受信任服务器。
在网上找了很久才找到解决方案。
This post is following on from “Lync 2013: Topology Builder encountered an issue and cannot publish this topology” after correcting the issue on my previous blog post I ran into the following issue;
A trusted server with the type “McxInternal” and the fully qualified domain name (FQDN) “EE01.lyncme.local” was found for a different Transport Layer Security (TLS) target
The error was also point to
The resolution for this was to open ADSI Edit and Select Configuration
Browse to CN=Services,CN=RTC Service,CN=Trusted Services and in here you will find the records that specify to McxInternal etc..
I suggest checking the records manually to see what they reference before deleting them. In my case all the records could be deleted as they was referencing to Servers and Pools names of my Lab which is not being used.
After deleting the none require records go back to your “Topology Builder” and “Re-Publish”. It should complete successfully
And In my case the warning was referencing the below error because of using a service account to install Lync 2013
Regards
最近 练习安装lync2013 在发布拓扑结构时遇到如下错误:
lync 错误: 已为不同的传输层安全性(TLS)目标找到类型为“McxInternal”且完全限定的域名(FQDN)为“lync.contoso.com”的受信任服务器。
在网上找了很久才找到解决方案。
This post is following on from “Lync 2013: Topology Builder encountered an issue and cannot publish this topology” after correcting the issue on my previous blog post I ran into the following issue;
A trusted server with the type “McxInternal” and the fully qualified domain name (FQDN) “EE01.lyncme.local” was found for a different Transport Layer Security (TLS) target
The error was also point to
The resolution for this was to open ADSI Edit and Select Configuration
Browse to CN=Services,CN=RTC Service,CN=Trusted Services and in here you will find the records that specify to McxInternal etc..
I suggest checking the records manually to see what they reference before deleting them. In my case all the records could be deleted as they was referencing to Servers and Pools names of my Lab which is not being used.
After deleting the none require records go back to your “Topology Builder” and “Re-Publish”. It should complete successfully
And In my case the warning was referencing the below error because of using a service account to install Lync 2013
Regards