下载并安装lsi MegaRAID raid卡 管理工具

单盘可以做raid0,只是没有任何增益效果,唯一就是能让raid卡识别硬盘。那些说raid0至少要2块硬盘的,都是理论课党,常玩阵列卡的都知道raid0无限制


背景:

lsi MegaRAID raid卡管理工具能查如下信息:
raid的level,

raid是几块物理硬盘构成的,

物理硬盘的制造商.


首先,介绍下Linux系统中查看raid厂商.


软件raid:查看raid级别,状态等信息
#cat /proc/mdstat

硬件raid:查看raid的厂商,型号,级别
#dmesg | grep -i raid
#cat /proc/scsi/scsi

比如如下的输出:
[html]   view plain  copy
  1. [root@rac1 disk]# dmesg | grep -i raid  
  2. [    2.657117] megaraid_sas 0000:01:00.0: irq 95 for MSI/MSI-X  
  3. [    2.657128] megaraid_sas 0000:01:00.0: irq 96 for MSI/MSI-X  
  4. [    2.657138] megaraid_sas 0000:01:00.0: irq 97 for MSI/MSI-X  
  5. [    2.657153] megaraid_sas 0000:01:00.0: irq 98 for MSI/MSI-X  
  6. [    2.657163] megaraid_sas 0000:01:00.0: irq 99 for MSI/MSI-X  
  7. [    2.657173] megaraid_sas 0000:01:00.0: irq 100 for MSI/MSI-X  
  8. [    2.657183] megaraid_sas 0000:01:00.0: irq 101 for MSI/MSI-X  
  9. [    2.657192] megaraid_sas 0000:01:00.0: irq 102 for MSI/MSI-X  
  10. [    2.657202] megaraid_sas 0000:01:00.0: irq 103 for MSI/MSI-X  
  11. [    2.657212] megaraid_sas 0000:01:00.0: irq 104 for MSI/MSI-X  
  12. [    2.657221] megaraid_sas 0000:01:00.0: irq 105 for MSI/MSI-X  
  13. [    2.657236] megaraid_sas 0000:01:00.0: irq 106 for MSI/MSI-X  
  14. [    2.657267] megaraid_sas 0000:01:00.0: [scsi0]: FW supports<96> MSIX vector,Online CPUs: <12>,Current MSIX <12>  
  15. [    2.700640] megaraid_sas 0000:01:00.0: Firmware supports 256 VD 256 PD  
  16. [    2.700656] megaraid_sas 0000:01:00.0: Driver supports 256 VD  256 PD  
  17. [    2.767437] megaraid_sas 0000:01:00.0: Controller type: MR,Memory size is: 2048MB  
  18. [    2.767439] megaraid_sas 0000:01:00.0: Firmware Crash dump feature is supported  
  19. [    2.788549] scsi host0: LSI SAS based MegaRAID driver  
  20. [root@rac1 disk]#   

这就确定是LSI的raid卡控制器.

下载并安装lsi MegaRAID raid卡 管理工具

下载网址:
http://www.avagotech.com/support/download-search
在如上的网址中,在搜索框里搜索"megacli",点击确定,找到Management Software and Tools (188) 下的 MegaCLI 5.5 P2  (这是命令行工具),
注意不要下载Latest MegaRAID Storage Manager (MSM) ,这个MSM是图形化的管理工具.

另:lsi已经被avago收购了.

如下是安装过程:

[html]   view plain  copy
  1. [root@rac1 ~]# cd tool/  
  2. [root@rac1 tool]# ll  
  3. total 7756  
  4. -rw-r--r-- 1 root root 7939395 Sep  8 15:39 8-07-14_MegaCLI.zip  
  5. [root@rac1 tool]# unzip 8-07-14_MegaCLI.zip   
  6. Archive:  8-07-14_MegaCLI.zip  
  7.   inflating: 8.07.14_MegaCLI.txt       
  8.   inflating: DOS/MegaCLI.exe           
  9.  extracting: FreeBSD/MegaCLI.zip       
  10.  extracting: FreeBSD/MegaCli64.zip     
  11.   inflating: Linux/MegaCli-8.07.14-1.noarch.rpm    
  12.   inflating: Solaris/MegaCli.pkg       
  13.   inflating: Windows/MegaCli.exe       
  14.   inflating: Windows/MegaCli64.exe     
  15. [root@rac1 tool]# ls -lrt  
  16. total 7824  
  17. -rw-r--r-- 1 root root   48298 Jan 19  2014 8.07.14_MegaCLI.txt  
  18. -rw-r--r-- 1 root root 7939395 Sep  8 15:39 8-07-14_MegaCLI.zip  
  19. drwxr-xr-x 2 root root    4096 Sep  8 15:39 DOS  
  20. drwxr-xr-x 2 root root    4096 Sep  8 15:39 FreeBSD  
  21. drwxr-xr-x 2 root root    4096 Sep  8 15:39 Linux  
  22. drwxr-xr-x 2 root root    4096 Sep  8 15:39 Solaris  
  23. drwxr-xr-x 2 root root    4096 Sep  8 15:39 Windows  
  24. [root@rac1 tool]# cd Linux/  
  25. [root@rac1 Linux]# ls -lrt  
  26. total 1516  
  27. -rw-r--r-- 1 root root 1549650 Dec 16  2013 MegaCli-8.07.14-1.noarch.rpm  
  28. [root@rac1 Linux]# rpm -ivh MegaCli-8.07.14-1.noarch.rpm   
  29. Preparing...                          ################################# [100%]  
  30. Updating / installing...  
  31.    1:MegaCli-8.07.14-1                ################################# [100%]  
  32. [root@rac1 Linux]# cd /opt/  
  33. [root@rac1 opt]# ls  
  34. MegaRAID  ORCLfmap  localyum  lsi  
  35. [root@rac1 opt]# cd MegaRAID/  
  36. [root@rac1 MegaRAID]# ls  
  37. MegaCli  
  38. [root@rac1 MegaRAID]# cd MegaCli/  
  39. [root@rac1 MegaCli]# ls -lrt  
  40. total 3188  
  41. -rwx------ 1 root root  540512 Dec 16  2013 libstorelibir-2.so.14.07-0  
  42. -rwxr-xr-x 1 root root 2720320 Dec 16  2013 MegaCli64  
  43. -rw-r--r-- 1 root root       0 Sep  8 15:39 install.log  
  44. lrwxrwxrwx 1 root root      48 Sep  8 15:39 libstorelibir-2.so -> /opt/MegaRAID/MegaCli/libstorelibir-2.so.14.07-0  
  45. [root@rac1 MegaCli]# ./MegaCli64 -PDList -aALL  
  46.                                         
  47. Adapter #0  
  48.   
  49.   
  50. Enclosure Device ID: 252  
  51. Slot Number: 0  
  52. Drive's position: DiskGroup: 0, Span: 0, Arm: 0  
  53. Enclosure position: N/A  
  54. Device Id: 0  
  55. WWN: 500003971843FAC5  
  56. Sequence Number: 2  
  57. Media Error Count: 0  
  58. Other Error Count: 0  
  59. Predictive Failure Count: 0  
  60. Last Predictive Failure Event Seq Number: 0  
  61. PD Type: SAS--------------------------------------------------------->>>硬盘接口是sas.  
  62.   
  63.   
  64. Raw Size: 279.396 GB [0x22ecb25c Sectors]  
  65. Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]  
  66. Coerced Size: 278.875 GB [0x22dc0000 Sectors]  
  67. Sector Size:  512  
  68. Logical Sector Size:  512  
  69. Physical Sector Size:  512  
  70. Firmware state: Online, Spun Up  
  71. Commissioned Spare : No  
  72. Emergency Spare : No  
  73. Device Firmware Level: 1004  
  74. Shield Counter: 0  
  75. Successful diagnostics completion on :  N/A  
  76. SAS Address(0): 0x500003971843fac6  
  77. SAS Address(1): 0x0  
  78. Connected Port Number: 0(path0)   
  79. Inquiry Data: TOSHIBA AL13SEB300      100466P0A0MHFWC9     -------------------------->>>硬盘制造商是东芝     
  80. FDE Capable: Not Capable  
  81. FDE Enable: Disable  
  82. Secured: Unsecured  
  83. Locked: Unlocked  
  84. Needs EKM Attention: No  
  85. Foreign State: None   
  86. Device Speed: 6.0Gb/s   
  87. Link Speed: 6.0Gb/s   
  88. Media Type: Hard Disk Device  
  89. Drive:  Not Certified  
  90. Drive Temperature :31C (87.80 F)  
  91. PI Eligibility:  No   
  92. Drive is formatted for PI information:  No  
  93. PI: No PI  
  94. Port-0 :  
  95. Port status: Active  
  96. Port's Linkspeed: 6.0Gb/s   
  97. Port-1 :  
  98. Port status: Active  
  99. Port's Linkspeed: 6.0Gb/s   
  100. Drive has flagged a S.M.A.R.T alert : No  
  101.   
  102.   
  103.   
  104.   
  105.   
  106.   
  107. Enclosure Device ID: 252  
  108. Slot Number: 1  
  109. Drive's position: DiskGroup: 0, Span: 0, Arm: 1  
  110. Enclosure position: N/A  
  111. Device Id: 1  
  112. WWN: 500003971843C221  
  113. Sequence Number: 2  
  114. Media Error Count: 0  
  115. Other Error Count: 0  
  116. Predictive Failure Count: 0  
  117. Last Predictive Failure Event Seq Number: 0  
  118. PD Type: SAS  
  119.   
  120.   
  121. Raw Size: 279.396 GB [0x22ecb25c Sectors]  
  122. Non Coerced Size: 278.896 GB [0x22dcb25c Sectors]  
  123. Coerced Size: 278.875 GB [0x22dc0000 Sectors]  
  124. Sector Size:  512  
  125. Logical Sector Size:  512  
  126. Physical Sector Size:  512  
  127. Firmware state: Online, Spun Up  
  128. Commissioned Spare : No  
  129. Emergency Spare : No  
  130. Device Firmware Level: 1004  
  131. Shield Counter: 0  
  132. Successful diagnostics completion on :  N/A  
  133. SAS Address(0): 0x500003971843c222  
  134. SAS Address(1): 0x0  
  135. Connected Port Number: 1(path0)   
  136. Inquiry Data: TOSHIBA AL13SEB300      100466P0A05SFWC9          
  137. FDE Capable: Not Capable  
  138. FDE Enable: Disable  
  139. Secured: Unsecured  
  140. Locked: Unlocked  
  141. Needs EKM Attention: No  
  142. Foreign State: None   
  143. Device Speed: 6.0Gb/s   
  144. Link Speed: 6.0Gb/s   
  145. Media Type: Hard Disk Device  
  146. Drive:  Not Certified  
  147. Drive Temperature :32C (89.60 F)  
  148. PI Eligibility:  No   
  149. Drive is formatted for PI information:  No  
  150. PI: No PI  
  151. Port-0 :  
  152. Port status: Active  
  153. Port's Linkspeed: 6.0Gb/s   
  154. Port-1 :  
  155. Port status: Active  
  156. Port's Linkspeed: 6.0Gb/s   
  157. Drive has flagged a S.M.A.R.T alert : No  
  158.   
  159.   
  160. -----以下限于篇幅,不再截取-------------  


如下是查看raid级别:

[html]   view plain  copy
  1. [root@rac1 MegaCli]# ./MegaCli64 -LDInfo -Lall -aALL  
  2.                                        
  3.   
  4. Adapter 0 -- Virtual Drive Information:  
  5. Virtual Drive: 0 (Target Id: 0)  
  6. Name                :  
  7. RAID Level          : Primary-5, Secondary-0, RAID Level Qualifier-3    --------------------------->>>>这是raid 5.  
  8. Size                : 836.625 GB  
  9. Sector Size         : 512  
  10. Is VD emulated      : No  
  11. Parity Size         : 278.875 GB  
  12. State               : Optimal  
  13. Strip Size          : 256 KB  
  14. Number Of Drives    : 4  
  15. Span Depth          : 1  
  16. Default Cache Policy: WriteBack, ReadAdaptive, Cached, No Write Cache if Bad BBU  
  17. Current Cache Policy: WriteThrough, ReadAdaptive, Cached, No Write Cache if Bad BBU  
  18. Default Access Policy: Read/Write  
  19. Current Access Policy: Read/Write  
  20. Disk Cache Policy   : Enabled  
  21. Encryption Type     : None  
  22. PI type: No PI  
  23.   
  24. Is VD Cached: No  
  25.   
  26.   
  27.   
  28. Exit Code: 0x00  
  29. [root@rac1 MegaCli]#   



如下截取自:

http://www.ttlsa.com/tools/megacli-tool-query-raid-status/

[html]   view plain  copy
  1. 命令使用:  
  2. #/opt/MegaCli  -LDInfo -Lall -aALL 查raid级别  
  3. #/opt/MegaCli -AdpAllInfo -aALL 查raid卡信息  
  4. #/opt/MegaCli -PDList -aALL 查看硬盘信息  
  5. #/opt/MegaCli -AdpBbuCmd -aAll 查看电池信息  
  6. #/opt/MegaCli -FwTermLog -Dsply -aALL 查看raid卡日志  
  7. #/opt/MegaCli -adpCount 【显示适配器个数】  
  8. #/opt/MegaCli -AdpGetTime –aALL 【显示适配器时间】  
  9. #/opt/MegaCli -AdpAllInfo -aAll    【显示所有适配器信息】  
  10. #/opt/MegaCli -LDInfo -LALL -aAll    【显示所有逻辑磁盘组信息】  
  11. #/opt/MegaCli -PDList -aAll    【显示所有的物理信息】  
  12. #/opt/MegaCli -AdpBbuCmd -GetBbuStatus -aALL |grep ‘Charger Status’ 【查看充电状态】  
  13. #/opt/MegaCli -AdpBbuCmd -GetBbuStatus -aALL【显示BBU状态信息】  
  14. #/opt/MegaCli -AdpBbuCmd -GetBbuCapacityInfo -aALL【显示BBU容量信息】  
  15. #/opt/MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL    【显示BBU设计参数】  
  16. #/opt/MegaCli -AdpBbuCmd -GetBbuProperties -aALL    【显示当前BBU属性】  
  17. #/opt/MegaCli -cfgdsply -aALL    【显示Raid卡型号,Raid设置,Disk相关信息】  

另外有价值的参考网址:

http://blog.chinaunix.net/uid-25135004-id-3139293.html

http://blog.csdn.net/smithereensman/article/details/51320499

出处:https://blog.csdn.net/msdnchina/article/details/52475383

你可能感兴趣的:(linux存储)