错误描述:Event filter with query "SELECT * FROM __InstanceModificationEvent WITHIN 60 WHERE TargetInstance ISA "Win32_Processor" AND TargetInstance.LoadPercentage > 99" could not be reactivated in namespace "//./root/CIMV2" because of error 0x80041003. Events cannot be delivered through this filter until the problem is corrected.

 

至于错误原因,那英文原文我翻译的不好,就不翻译了 O(∩_∩)O

 

解决方法:

一种方法是下载工具http://go.microsoft.com/?linkid=9775756 运行即可解决问题。

另一种方法是:新建一个文本文档,把下面的复制进去,另存为到D盘Workaround.vbs,然后用管理员身份运行cmd.exe,改变目录到D盘,运行这个vbs即可。

strComputer = "."

Set objWMIService = GetObject("winmgmts:" _
& "{impersonationLevel=impersonate}!\\" _
& strComputer & "\root\subscription")

Set obj1 = objWMIService.ExecQuery("select * from __eventfilter where name='BVTFilter' and query='SELECT * FROM __InstanceModificationEvent WITHIN 60 WHERE TargetInstance ISA ""Win32_Processor"" AND TargetInstance.LoadPercentage > 99'")

For Each obj1elem in obj1

set obj2set = obj1elem.Associators_("__FilterToConsumerBinding")

set obj3set = obj1elem.References_("__FilterToConsumerBinding")

For each obj2 in obj2set

WScript.echo "Deleting the object"

WScript.echo obj2.GetObjectText_

obj2.Delete_

next

For each obj3 in obj3set

WScript.echo "Deleting the object"

WScript.echo obj3.GetObjectText_

obj3.Delete_

next

WScript.echo "Deleting the object"

WScript.echo obj1elem.GetObjectText_

obj1elem.Delete_

Next

 

摘自:http://support.microsoft.com/kb/2545227

原文转自:http://hi.baidu.com/lian_zhang/item/5fea54c12e3009bb0d0a7b34