System Bootstrap, Version 5.1(2)
Copyright (c) 1994-1999 by cisco Systems, Inc.
Presto processor with 32768 Kbytes of main memory
Autoboot executing command: "boot bootflash:cat5000-sup3.5-5-13a.bin"
Loading Network Management Processor image
Uncompressing file:
#########################################################
###################################
##########################################################
##################################
############################################
System Power On Diagnostics
NVRAM Size ...................512 KB
Testing ID Prom ..............Passed
DPRAM Size ...................16 KB
Testing DPRAM Data 0x55 ......Passed
Testing DPRAM Data 0xaa ......Passed
Testing DPRAM Address ........Passed
Clearing DPRAM ...............Done
System DRAM Memory Size ......32 MB
Testing DRAM Data 0x55 .......Passed
Testing DRAM Data 0xaa .......Passed
Testing DRAM Address .........Passed
Clearing DRAM ................Done
EARLIII ......................Present
Testing EARLIII RAM ..........Passed
Testing EARL Serial Prom .....Passed
Level2 Cache .................Present
Testing Level2 Cache .........Passed
Boot image: bootflash:cat5000-sup3.5-5-13a.bin
Downloading epld sram device please wait ...
Programming successful for Altera 10K50 SRAM EPLD
Running System Diagnostics from this Supervisor (Module 1)
This may take up to 2 minutes....please wait
Minor hardware problem in Module # 1
Use 'show test 1' to see results of tests.
Cisco Systems Console
Enter password:
Console>
2009 Feb 18 00:30:50 %MLS-5-NDEDISABLED:Netflow Data Export disabled
Console>
2009 Feb 18 00:30:50 %SYS-5-MOD_OK:Module 1 is online
Console>
Console> (enable) sh conf
This command shows non-default configurations only.
Use 'show config all' to show both default and non-default configurations.
......
...............
................
................
..
begin
!
# ***** NON-DEFAULT CONFIGURATION *****
!
!
#time: Wed Feb 18 2009, 00:30:56
!
#version 5.5(13a)
!
set password $2$Bi8o$ChqfU8OMam7rctD0tCEgO/
set enablepass $2$r3XI$Rrwo/IEYLZVpoPMxtFXFT1
!
#frame distribution method
set port channel all distribution mac both
!
#snmp
set snmp community read-only netbar
set snmp community read-write
set snmp community read-write-all
!
#ip
set interface sc0 1 192.168.88.1/255.255.0.0 192.168.255.255
set ip route 0.0.0.0/0.0.0.0 192.168.0.254
!
#set boot command
set boot config-register 0x102
set boot system flash bootflash:cat5000-sup3.5-5-13a.bin
!
#mls
set mls disable ip
set mls nde disable
!
# default port status is enable
!
!
--More--2009 Feb 18 00:31:13 %SYS-5-MOD_OK:Module 2 is online
#module 1 : 2-port 1000BaseSX Supervisor
set port disable 1/1-2
--More--2009 Feb 18 00:31:18 %SYS-5-MOD_OK:Module 4 is online
---
Console> (enable) sh flash
-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1 .. ffffffff f28db5fe 4371c 12 13979 Mar 15 2006 15:28:22 myconfig.txt
2 .. ffffffff eda99c3e 500a48 24 4969129 Jun 16 2006 11:31:15 cat5000-sup3.5-5-13a.bin
3 .. ffffffff e54af2fc 506d24 12 25178 Aug 30 2007 13:14:41 myswitch.cfg
Console> (enable) sh version
WS-C5505 Software, Version McpSW: 5.5(13a) NmpSW: 5.5(13a)
Copyright (c) 1995-2002 by Cisco Systems
NMP S/W compiled on Feb 1 2002, 19:47:47
MCP S/W compiled on Feb 01 2002, 19:41:58
System Bootstrap Version: 5.1(2)
Hardware Version: 1.0 Model: WS-C5505 Serial #: 066539470
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5530 015563875 Hw : 3.4
Fw : 5.1(2)
Fw1: 4.4(1)
Sw : 5.5(13a)
WS-F5531 015558139 Hw : 2.0
WS-U5534 024709159 Hw : 1.2
2 24 WS-X5234 029348441 Hw : 1.1
Fw : 4.5(2)
Sw : 5.5(13a)
4 24 WS-X5225R 017407516 Hw : 3.3
Fw : 4.3(1)
Sw : 5.5(13a)
5 24 WS-X5225R 020235258 Hw : 3.3
Fw : 4.3(1)
Sw : 5.5(13a)
DRAM FLASH NVRAM
Module Total Used Free Total Used Free Total Used Free
------ ------- ------- ------- ------- ------- ------- ----- ----- -----
1 32768K 19644K 13124K 8192K 5660K 2532K 512K 204K 308K
Uptime is 0 day, 0 hour, 5 minutes
Console> (enable) sh module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseSX Supervisor WS-X5530 yes ok
2 2 24 10/100BaseTX Ethernet WS-X5234 no ok
4 4 24 10/100BaseTX Ethernet WS-X5225R no ok
5 5 24 10/100BaseTX Ethernet WS-X5225R no other
Mod Module-Name Serial-Num
--- ------------------- --------------------
1 00015563875
2 00029348441
4 00017407516
5 00020235258
Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ---------- -----------------
1 00-50-54-16-6c-00 to 00-50-54-16-6f-ff 3.4 5.1(2) 5.5(13a)
2 00-04-c0-33-b7-a8 to 00-04-c0-33-b7-bf 1.1 4.5(2) 5.5(13a)
4 00-30-7b-32-07-78 to 00-30-7b-32-07-8f 3.3 4.3(1) 5.5(13a)
5 00-01-63-52-35-b0 to 00-01-63-52-35-c7 3.3 4.3(1) 5.5(13a)
Mod Sub-Type Sub-Model Sub-Serial Sub-Hw
--- -------- --------- ---------- ------
1 NFFC II WS-F5531 0015558139 2.0
1 uplink WS-U5534 0024709159 1.2
Console> (enable) sh port
Port Name Status Vlan Level Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
1/1 disabled 1 normal full 1000 1000BaseSX
1/2 disabled 1 normal full 1000 1000BaseSX
2/1 notconnect 1 normal auto auto 10/100BaseTX
2/2 notconnect 1 normal auto auto 10/100BaseTX
2/3 notconnect 1 normal auto auto 10/100BaseTX
Console> (enable) set port enable 1/1
Port 1/1 enabled.
Console> (enable) set port enable 1/2
Failed to enable port 1/2.
Port may be faulty.
Console> (enable) sh port
Port Name Status Vlan Level Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
1/1 notconnect 1 normal full 1000 1000BaseSX
1/2 disabled 1 normal full 1000 1000BaseSX
2/1 notconnect 1 normal auto auto 10/100BaseTX
2/2 notconnect 1 normal auto auto 10/100BaseTX
2009 Feb 18 00:38:20 %SYS-3-MOD_FAIL:Module 5 failed to come online
Console> (enable) 2009 Feb 18 00:40:21 %SYS-5-MOD_REMOVE:Module 5 has been removed
2009 Feb 18 00:40:27 %SYS-5-MOD_INSERT:Module 5 has been inserted
Console> (enable) Syndiags failed on Module Number 5
Use 'show test 5' to see results of tests.
2009 Feb 18 00:47:40 %SYS-3-MOD_FAIL:Module 5 failed to come online
2009 Feb 18 00:56:15 %SYS-5-MOD_INSERT:Module 3 has been inserted
2009 Feb 18 00:56:45 %SYS-3-MOD_CFGMISMATCH1:Module 3 configuration mismatch. Ports
disabled
2009 Feb 18 00:56:45 %SYS-3-MOD_CFGMISMATCH2:*Config:24 port 10/100BaseTX (RJ-45)
2009 Feb 18 00:56:45 %SYS-3-MOD_CFGMISMATCH3:*Actual:10/100BaseTX Ethernet
2009 Feb 18 00:56:45 %SYS-3-MOD_CFGMISMATCH4:Insert config type module or do a 'clear config
3'
2009 Feb 18 00:56:48 %SYS-5-MOD_OK:Module 3 is online
-----------
onsole> (enable) sh module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseSX Supervisor WS-X5530 yes ok
2 2 24 10/100BaseTX Ethernet WS-X5234 no ok
3 3 24 10/100BaseTX Ethernet WS-X5225R no ok
Module 3 mismatch of config and actual type. Ports disabled
Config: 24 port 10/100BaseTX (RJ-45) , Actual: 10/100BaseTX Ethernet
Insert config module type or do a 'clear config 3'
4 4 24 10/100BaseTX Ethernet WS-X5225R no ok
Mod Module-Name Serial-Num
--- ------------------- --------------------
1 00015563875
2 00029348441
3 00020235258
4 00017407516
Mod MAC-Address(es) Hw Fw Sw
--- -------------------------------------- ------ ---------- -----------------
1 00-50-54-16-6c-00 to 00-50-54-16-6f-ff 3.4 5.1(2) 5.5(13a)
2 00-04-c0-33-b7-a8 to 00-04-c0-33-b7-bf 1.1 4.5(2) 5.5(13a)
3 00-01-63-52-35-b0 to 00-01-63-52-35-c7 3.3 4.3(1) 5.5(13a)
4 00-30-7b-32-07-78 to 00-30-7b-32-07-8f 3.3 4.3(1) 5.5(13a)
Console> (enable) sh config
------
#module 3 : 24-port 10/100BaseTX Ethernet
set port disable 3/1-24
-------
-------
Console> (enable) set port enable 3/1-24
Port(s) 3/1-24 enabled.
Console> (enable) sh module
Mod Slot Ports Module-Type Model Sub Status
--- ---- ----- ------------------------- ------------------- --- --------
1 1 2 1000BaseSX Supervisor WS-X5530 yes ok
2 2 24 10/100BaseTX Ethernet WS-X5234 no ok
3 3 24 10/100BaseTX Ethernet WS-X5225R no ok
4 4 24 10/100BaseTX Ethernet WS-X5225R no ok