Lync 小技巧-13-Lync Server 2013与Exchange Server 2013 UM集成-错误-4999-1038

错误:

1) 服务-启动不了

clip_image001

现在是启动的,但是你知道,在这之前,总在重启…

2) 日志

clip_image002

3) 事件-1038

clip_image003

The Microsoft Exchange Unified Messaging Call Router wasn't able to start. More information: "System.IO.FileNotFoundException: Could not load file or assembly 'Microsoft.Rtc.Collaboration, Version=5.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35' or one of its dependencies. The system cannot find the file specified.

File name: 'Microsoft.Rtc.Collaboration, Version=5.0.0.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35'

at Microsoft.Exchange.UM.UcmaPlatform.UcmaCallRouterPlatform..ctor(LocalizedString serviceName, LocalizedString serverName, UMADSettings config)

at Microsoft.Exchange.UM.UcmaPlatform.UcmaPlatform.CreateCallRouterVoipPlatform(LocalizedString serviceName, LocalizedString serverName, UMADSettings config)

at Microsoft.Exchange.UM.CallRouter.UMCallRouter.InternalStart()

at Microsoft.Exchange.UM.UMCore.UMServiceBase.StartService()

at Microsoft.Exchange.UM.UMCore.UMServiceBase.OnStartInternal(String[] args)

WRN: Assembly binding logging is turned OFF.

To enable assembly bind failure logging, set the registry value [HKLM\Software\Microsoft\Fusion!EnableLog] (DWORD) to 1.

Note: There is some performance penalty associated with assembly bind failure logging.

To turn this feature off, remove the registry value [HKLM\Software\Microsoft\Fusion!EnableLog].

"

4) 事件-4999

clip_image004

Watson report about to be sent for process id: 26340, with parameters: E12, c-RTL-AMD64, 15.00.0620.029, M.E.UM.CallRouter, M.E.UM.UcmaPlatform, M.E.U.U.UcmaCallRouterPlatform..ctor, S.IO.FileNotFoundException, b6da, 15.00.0620.020.

ErrorReportingEnabled: False

5) 启动不了,痛苦吧 ?

方法:

1) 安装-Unified Communications Managed API 4.0 Runtime

clip_image006

clip_image007

clip_image008

clip_image009

2) 启动-服务

clip_image001[1]

正常了!