Log摘要 System Configuration:Oracle Corporationsun4u Sun Fire 880 System clock frequency: 150 MHz Memory size: 8192 Megabytes ========================= CPUs =============================================== RunE$CPUCPU BrdCPUMHzMB Impl.Mask --- ----- ---- ---- ------- ---- A09008.0 US-III+2.3 B19008.0 US-III+2.3 A29008.0 US-III+2.3 B39008.0 US-III+2.3 ========================= Memory Configuration =============================== LogicalLogicalLogical MCBankBankBankDIMMInterleaveInterleaved BrdIDnumsizeStatusSizeFactorwith ------------------------------------------------------- A00512MBno_status256MB8-way0 A01512MBno_status256MB8-way0 A02512MBno_status256MB8-way0 A03512MBno_status256MB8-way0 B10512MBno_status256MB8-way1 B11512MBno_status256MB8-way1 B12512MBno_status256MB8-way1 B13512MBno_status256MB8-way1 A20512MBno_status256MB8-way0 A21512MBno_status256MB8-way0 A22512MBno_status256MB8-way0 A23512MBno_status256MB8-way0 B30512MBno_status256MB8-way1 B31512MBno_status256MB8-way1 B32512MBno_status256MB8-way1 B33512MBno_status256MB8-way1 ========================= IO Cards ========================= BusMax IOPort BusFreq BusDev, BrdTypeIDSide Slot MHzFreq Func State NameModel ---- ---- ---- ---- ---- ---- ---- ---- ----- ------------------------------------------------------ I/OPCI8B333332,0okSUNW,qlc-pci1077,2300.1077.106.1+ I/OPCI9B633332,0okSUNW,qlc-pci1077,2300.1077.106.1+ I/OPCI9B533333,0okSUNW,qlc-pci1077,2300.1077.106.1+ I/OPCI9B433334,0okSUNW,qlc-pci1077,2300.1077.106.1+ No failures found in System =========================== ========================= Environmental Status ========================= System Temperatures (Celsius): ------------------------------- DeviceTemperatureStatus --------------------------------------- CPU069OK CPU169OK CPU270OK CPU366OK MB32OK IOB29OK DBP030OK ================================= Front Status Panel: ------------------- Keyswitch position: NORMAL System LED Status: GEN FAULTREMOVE [ ON][OFF] DISK FAULTPOWER FAULT [OFF][OFF] LEFT THERMAL FAULT RIGHT THERMAL FAULT [ ON][OFF] LEFT DOORRIGHT DOOR [OFF][OFF] ================================= Disk Status: PresenceFault LEDRemove LED DISK0: [PRESENT][OFF][OFF] DISK1: [PRESENT][OFF][OFF] DISK2: [PRESENT][OFF][OFF] DISK3: [PRESENT][OFF][OFF] DISK4: [PRESENT][OFF][OFF] DISK5: [PRESENT][OFF][OFF] DISK6: [EMPTY] DISK7: [EMPTY] DISK8: [EMPTY] DISK9: [EMPTY] DISK10: [EMPTY] DISK11: [EMPTY] ================================= Fan Bank : ---------- BankSpeedStatusFan State ( RPMS ) ------------------------------ CPU0_PRIM_FAN2189[ENABLED]OK CPU1_PRIM_FAN2290[ENABLED]OK CPU0_SEC_FAN0[DISABLED]OK CPU1_SEC_FAN0[DISABLED]OK IO0_PRIM_FAN0[DISABLED]ERROR IO1_PRIM_FAN0[DISABLED]ERROR IO0_SEC_FAN3947[ENABLED]OK IO1_SEC_FAN3896[ENABLED]OK IO_BRIDGE_PRIM_FAN3333[ENABLED]OK IO_BRIDGE_SEC_FAN0[DISABLED]OK ================================= Power Supplies: --------------- Current Drain: SupplyStatusFan FailTemp FailCS Fail3.3V5V12V48V ------------------------------------------------------ PS0GOOD6323 PS1GOOD6323 PS2GOOD6323 ========================= HW Revisions ======================================= System PROM revisions: ---------------------- OBP 4.6.7 2002/07/24 15:42 IO ASIC revisions: ------------------ Port ModelIDStatus Version -------- ---- ------ ------- Schizo8ok4 Schizo9ok4 # System Configuration:Oracle Corporationsun4u Sun Fire 880 System clock frequency: 150 MHz Memory size: 8192 Megabytes ========================= CPUs =============================================== RunE$CPUCPU BrdCPUMHzMB Impl.Mask --- ----- ---- ---- ------- ---- A09008.0 US-III+2.3 B19008.0 US-III+2.3 A2 9008.0 US-III+2.3 B39008.0 US-III+2.3 ========================= Memory Configuration =============================== LogicalLogicalLogical MCBankBankBankDIMMInterleaveInterleaved Brd IDnumsizeStatusSizeFactorwith ------------------------------------------------------- A00512MBno_status256MB8-way0 A01512MBno_status256MB8-way0 A02512MBno_status256MB8-way0 A03512MBno_status256MB8-way0 B10512MBno_status256MB8-way1 B11512MBno_status256MB8-way1 B12512MBno_status256MB8-way1 B13512MBno_status256MB8-way1 A20512MBno_status256MB8-way0 A21512MBno_status256MB8-way0 A22512MBno_status256MB8-way0 A23512MBno_status256MB8-way0 B30512MBno_status256MB8-way1 B31512MBno_status256MB8-way1 B32512MBno_status256MB8-way1 B33512MBno_status256MB8-way1 ========================= IO Cards ========================= BusMax IOPort BusFreq BusDev, BrdTypeIDSide Slot MHzFreq Func State NameModel ---- ---- ---- ---- ---- ---- ---- ---- ----- ------------------------------------------------------ I/OPCI8B333332,0okSUNW,qlc-pci1077,2300.1077.106.1+ I/OPCI9B633332,0okSUNW,qlc-pci1077,2300.1077.106.1+ I/OPCI9B533333,0okSUNW,qlc-pci1077,2300.1077.106.1+ I/OPCI9B433334,0okSUNW,qlc-pci1077,2300.1077.106.1+ No failures found in System #dmesg Jan 15 11:39:50 csu picld[203]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected Jan 15 13:16:53 csu picld[208]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected Jan 15 14:46:34 csu picld[204]: [ID 625010 daemon.error] WARNING: Device IO0_PRIM_FAN failure detected |
客户反应,SUN V880前面板,温度LED指示灯橙黄色。
通过系统错误信息得知:
IO0_PRIM_FAN0[DISABLED]ERROR
IO1_PRIM_FAN0[DISABLED]ERROR
通过dmesg 查看出IO0_PRIM_FAN 检查有问题,不排除IO1_PRIM_FAN和机器内部灰尘过多导致.
因此,先准备2块PCI I/O Fan Tray和吸尘器(有可能机器内部灰尘过多,导致风扇告警),同时解决此次故障。
注意 |
确保系统关机,电源断开
操作时,使用防静电护腕 添加或更换硬件组件之前请作好数据备份。如果部件未正确安装,则可能会导致数据丢失。 |
准备确认项 |
||
类型 |
准备项 |
状态 |
硬件 |
笔记本一台 |
已准备就绪 |
串口线一根 |
已准备就绪 |
|
一字、十字螺丝刀各一把 |
已准备就绪 |
|
防静电护腕一个 |
已准备就绪 |
|
新2块IO_PRIM_FAN |
已准备就绪 |
|
软件 |
||
其它 |
||
操作项列表 |
|||
序号 |
操作项 |
操作内容 |
状态 |
1 |
确认系统关机 |
建议客户应用及业务数据备份 |
|
2 |
使用POST诊断 |
定位系统故障的确切位置 |
|
3 |
佩戴防静电护腕 |
确认已经佩戴防静电护腕,并且防静电护腕连接到机柜上的未涂漆部分 |
|
4 |
断开电源 |
断开主电源和次电源 |
|
5 |
移除服务检修盖 |
||
6 |
拆除处理器板 |
||
7 |
将取下的处理器板放置在防静电的材质表面 |
||
8 |
拆开移除处理器前盖 |
||
9 |
确认IO_PRIM_FAN位置 |
||
10 |
从防静电包装中取出IO_PRIM_FAN |
||
11 |
安装IO_PRIM_FAN |
||
12 |
重新安装处理器板 |
||
13 |
确认故障影响消失 |
确认新更换的硬件无告警 |
|
确认新的硬件在系统中就绪 |
|||
用户确认应用及业务数据不受影响 |
|||
14 |
收尾 |
清理现场,结束工作 |