基于ESXI5.0或5.1安装Windows Server 2012,在除C盘外新增分区或硬盘时可能会遇到新添加的分区在administrator下无新建删除修改权限,vmware tools安装报错“microsoft runtime dll安装程序未能完成安装”等问题,解决办法如下:

Found a solution to this issue in case it helps anyone else out. In VMware ESXi 5.0 all hard disks added to the VM will be detected as removable. To get everything working properly HotPlug capability needs to be disabled as described here:

http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1012225

Disabling the HotAdd/HotPlug capability in ESXi 5.x and ESXi/ESX 4.x virtual machines (1012225)

Symptoms

  • NICs and SCSI controllers appear as removable devices.

  • The Safely Remove Hardware option for the virtual hardware appears in the Windows System Tray.

  • If you are using VMware View, you notice that View desktops which have persistent disks are disconnecting.

Purpose

This article describes how to disable the HotPlug capability on removable devices.

Resolution

You can disable HotPlug capability using the vSphere Client or by editing the .vmx file.

Note: You can disable HotPlug capability for PCI devices such as e1000 or vmxnet2 NICs.

To disable HotPlug capability using the vSphere Client:

  1. Connect to the ESXi/ESX host or vCenter Server using the vSphere Client.

  2. Power off the virtual machine.

  3. Right-click the virtual machine and click Edit Settings.

  4. Click the Options tab.

  5. Click General > Configuration Parameters > Add Row.

  6. Insert a new row with the name devices.hotplug and a value of false.

  7. Power on the virtual machine.


To disable HotPlug capability by editing the .vmx file:

  1. Power off the virtual machine.

  2. Access the ESXi/ESX service console using an SSH client.

  3. Open the virtual machine configuration file (.vmx) in a text editor. The default location is:

    /vmfs/volumes/datastore_name/vm_name/vm_name.vmx

  4. Add the line:

    devices.hotplug = "false"

    Note: This setting does not interfere with HotPlug CPU/memory.

  5. Save and close the file.

  6. Power on the virtual machine.


Note: If you are using VMware View, follow one of the above procedures for the parent virtual machine first, then follow these steps:

  1. Create a new snapshot of the parent virtual machine:

    1. In the vSphere Client, right-click the parent virtual machine and click Snapshot > Take Snapshot.

    2. Give the snapshot a name and description.

    3. Click OK.


  2. Recompose the affected pools to this new snapshot:

    1. In the View Manager console, select a pool and open it.

    2. Click View Composer > Recompose, and select the newly created snapshot.

    3. Click Next.

    4. Configure the Schedule and Warnings options.

    5. Click Next.

    6. Review the confirmation information.

    7. Click Finish and verify that the recompose operation successfully completes.