DS5020磁盘impending failure故障处理

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23228

Event type: 101E

Event category: Error

Priority: Critical

Event needs attention: true

Event send alert: true

Event visibility: true

Description: Impending drive failure detected by controller

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23230

Event type: 1012

Event category: Error

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Destination driver error

Event specific codes: 204/3/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23231

Event type: 6008

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Stable storage drive unusable

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23232

Event type: 2226

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Drive spun down

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23233

Event type: 226C

Event category: Failure

Priority: Critical

Event needs attention: true

Event send alert: true

Event visibility: true

Description: Drive failure

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:09

Sequence number: 23234

Event type: 2215

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Drive marked failed

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 9

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:12

Sequence number: 23252

Event type: 2224

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Reconstruction started

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 16

Logged by: Controller in slot A

 

Date/Time: 18-11-26 6:20:12

Sequence number: 23253

Event type: 2025

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Reconstruction started

Event specific codes: 0/0/0

Component type: Logical Drive

Component location: Logical Drive SVC_Raid5_8disk_2_lun1

Logged by: Controller in slot A

 

Date/Time: 18-11-26 8:05:09

Sequence number: 23256

Event type: 2025

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Reconstruction started

Event specific codes: 0/0/0

Component type: Logical Drive

Component location: Logical Drive SVC_Raid5_8disk_2_lun2

Logged by: Controller in slot B

 

Date/Time: 18-11-26 8:05:09

Sequence number: 23257

Event type: 2026

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Reconstruction completed

Event specific codes: 0/0/0

Component type: Logical Drive

Component location: Logical Drive SVC_Raid5_8disk_2_lun1

Logged by: Controller in slot A

 

Date/Time: 18-11-26 10:20:51

Sequence number: 23259

Event type: 2026

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Reconstruction completed

Event specific codes: 0/0/0

Component type: Logical Drive

Component location: Logical Drive SVC_Raid5_8disk_2_lun2

Logged by: Controller in slot B

 

Date/Time: 18-11-26 10:20:51

Sequence number: 23261

Event type: 2206

Event category: Internal

Priority: Informational

Event needs attention: false

Event send alert: false

Event visibility: true

Description: Reconstruction completed

Event specific codes: 0/0/0

Component type: Drive

Component location: Enclosure 85, Slot 16

Logged by: Controller in slot B

 

DS5020磁盘impending failure故障处理_第1张图片

 

DS5020磁盘impending failure故障处理_第2张图片

通过查看日志,Enclosure 85,SLOT 9的磁盘已经marked failedService actionremovalallowedYesEnclosure 85,SLOT 16的热备磁盘已经加入raid组,磁盘对应的raid组已经Reconstruction completed

DS5020磁盘impending failure故障处理_第3张图片

 

DS5020磁盘impending failure故障处理_第4张图片

但是,在Storage Manager界面仍然显示Enclosure 85,SLOT 9的磁盘状态为Impending drive failure可以考虑直接更换Enclosure 85,SLOT 9的磁盘

DS5020磁盘impending failure故障处理_第5张图片

更换磁盘的时候注意磁盘的firmware Version,如果版本不兼容可能会更换失败。

 

更换流程:

 

将故障硬盘从插槽中取出:

DS5020磁盘impending failure故障处理_第6张图片

等待1分钟将新盘插入插槽:

DS5020磁盘impending failure故障处理_第7张图片

此时故障硬盘显示为replaced状态:

DS5020磁盘impending failure故障处理_第8张图片

与此硬盘相关的lun将进行copyback:

DS5020磁盘impending failure故障处理_第9张图片

等待所有的lun的copyback完成,硬盘的状态变为Optimal

DS5020磁盘impending failure故障处理_第10张图片

 

至此,硬盘更换流程完成。