Date/Time: 18-11-26 6:20:09
Sequence number: 23228
Event type: 101E
Event category: Error
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Impending drive failure detected by controller
Event specific codes: 0/0/0
Component type: Drive
Component location: Enclosure 85, Slot 9
Logged by: Controller in slot A
Date/Time: 18-11-26 6:20:09
Sequence number: 23230
Event type: 1012
Event category: Error
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Destination driver error
Event specific codes: 204/3/0
Component type: Drive
Component location: Enclosure 85, Slot 9
Logged by: Controller in slot A
Date/Time: 18-11-26 6:20:09
Sequence number: 23231
Event type: 6008
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Stable storage drive unusable
Event specific codes: 0/0/0
Component type: Drive
Component location: Enclosure 85, Slot 9
Logged by: Controller in slot A
Date/Time: 18-11-26 6:20:09
Sequence number: 23232
Event type: 2226
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Drive spun down
Event specific codes: 0/0/0
Component type: Drive
Component location: Enclosure 85, Slot 9
Logged by: Controller in slot A
Date/Time: 18-11-26 6:20:09
Sequence number: 23233
Event type: 226C
Event category: Failure
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Drive failure
Event specific codes: 0/0/0
Component type: Drive
Component location: Enclosure 85, Slot 9
Logged by: Controller in slot A
Date/Time: 18-11-26 6:20:09
Sequence number: 23234
Event type: 2215
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Drive marked failed
Event specific codes: 0/0/0
Component type: Drive
Component location: Enclosure 85, Slot 9
Logged by: Controller in slot A
Date/Time: 18-11-26 6:20:12
Sequence number: 23252
Event type: 2224
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Reconstruction started
Event specific codes: 0/0/0
Component type: Drive
Component location: Enclosure 85, Slot 16
Logged by: Controller in slot A
Date/Time: 18-11-26 6:20:12
Sequence number: 23253
Event type: 2025
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Reconstruction started
Event specific codes: 0/0/0
Component type: Logical Drive
Component location: Logical Drive SVC_Raid5_8disk_2_lun1
Logged by: Controller in slot A
Date/Time: 18-11-26 8:05:09
Sequence number: 23256
Event type: 2025
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Reconstruction started
Event specific codes: 0/0/0
Component type: Logical Drive
Component location: Logical Drive SVC_Raid5_8disk_2_lun2
Logged by: Controller in slot B
Date/Time: 18-11-26 8:05:09
Sequence number: 23257
Event type: 2026
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Reconstruction completed
Event specific codes: 0/0/0
Component type: Logical Drive
Component location: Logical Drive SVC_Raid5_8disk_2_lun1
Logged by: Controller in slot A
Date/Time: 18-11-26 10:20:51
Sequence number: 23259
Event type: 2026
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Reconstruction completed
Event specific codes: 0/0/0
Component type: Logical Drive
Component location: Logical Drive SVC_Raid5_8disk_2_lun2
Logged by: Controller in slot B
Date/Time: 18-11-26 10:20:51
Sequence number: 23261
Event type: 2206
Event category: Internal
Priority: Informational
Event needs attention: false
Event send alert: false
Event visibility: true
Description: Reconstruction completed
Event specific codes: 0/0/0
Component type: Drive
Component location: Enclosure 85, Slot 16
Logged by: Controller in slot B
通过查看日志,Enclosure 85,SLOT 9的磁盘已经marked failed,Service action(removal)allowed:Yes,Enclosure 85,SLOT 16的热备磁盘已经加入raid组,磁盘对应的raid组已经Reconstruction completed。
但是,在Storage Manager界面仍然显示Enclosure 85,SLOT 9的磁盘状态为Impending drive failure,可以考虑直接更换Enclosure 85,SLOT 9的磁盘
更换磁盘的时候注意磁盘的firmware Version,如果版本不兼容可能会更换失败。
更换流程:
将故障硬盘从插槽中取出:
等待1分钟将新盘插入插槽:
此时故障硬盘显示为replaced状态:
与此硬盘相关的lun将进行copyback:
等待所有的lun的copyback完成,硬盘的状态变为Optimal:
至此,硬盘更换流程完成。