Linux下powerpath共享磁盘名称不一致处理方法

    我们知道在SAN网络中,由于光纤交换机会有多条链路接入主机,所以会存在设备多名称现象,也就是一台存储被识别多次,具体根据连接的链路情况,并且对于连接到的LUN在主机上的LINUX系统上会发生/dev/sd*每次重启动设备名变化的问题,所以对于此问题,我们可以采取两种方式,一是高版本的linux可以通过udev来配置,将LUN设备号固定下来,二是采用第三方的动态多路径软件配置多路径聚合,从而固定盘符名称,在此主要是对powerpath动态多路径软件配置存在的问题做以说明。

在powerpath配置安装成功可能会存在这个问题,也就是两台主机识别到的伪设备名称对应的LUN不一致,例如如下所示:


在主机DBTEST1上获取的信息如下:

DBTest1:/home/oracle # powermt display dev=all

Pseudo name=emcpowerb 

CLARiiON ID=FCNCX093300010 [Storage Group 2]

Logical device ID=600601601EA02500326149A0207AE111 [LUN 10]

state=alive; policy=BasicFailover; priority=0; queued-IOs=0; 

Owner: default=SP A, current=SP A       Array failover mode: 1

==============================================================================

--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---

###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors

==============================================================================

   0 qla2xxx                  sde       SP B1     unlic   alive       0      0

   0 qla2xxx                  sdj       SP A1     unlic   alive       0      0

   1 qla2xxx                  sdk       SP B0     active  alive       0      0

   1 qla2xxx                  sdo       SP A0     active  alive       0      0

 

Pseudo name=emcpowera

CLARiiON ID=FCNCX093300010 [Storage Group 2]

Logical device ID=600601601EA02500F22E8FC2207AE111 [LUN 11]

state=alive; policy=BasicFailover; priority=0; queued-IOs=0; 

Owner: default=SP A, current=SP A       Array failover mode: 1

==============================================================================

--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---

###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors

==============================================================================

   0 qla2xxx                  sdg       SP B1     unlic   alive       0      0

   0 qla2xxx                  sdl       SP A1     unlic   alive       0      0

   1 qla2xxx                  sdm       SP B0     active  alive       0      0

   1 qla2xxx                  sdp       SP A0     active  alive       0      0

 

Pseudo name=emcpowerc

CLARiiON ID=FCNCX093300010 [Storage Group 2]

Logical device ID=600601601EA02500FA322E81207AE111 [LUN 1]

state=alive; policy=BasicFailover; priority=0; queued-IOs=0; 

Owner: default=SP A, current=SP A       Array failover mode: 1

==============================================================================

--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---

###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors

==============================================================================

   0 qla2xxx                  sdc       SP B1     unlic   alive       0      0

   0 qla2xxx                  sdh       SP A1     unlic   alive       0      0

   1 qla2xxx                  sdi       SP B0     active  alive       0      0

   1 qla2xxx                  sdn       SP A0     active  alive       0      0

而在主机DBTEST2上识别的信息如下:

DBTest2:~ # powermt display dev=all

Pseudo name=emcpowera 

CLARiiON ID=FCNCX093300010 [Storage Group 2]

Logical device ID=600601601EA02500326149A0207AE111 [LUN 10]

state=alive; policy=BasicFailover; priority=0; queued-IOs=0; 

Owner: default=SP A, current=SP A       Array failover mode: 1

==============================================================================

--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---

###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors

==============================================================================

   0 qla2xxx                  sde       SP B1     active  alive       0      0

   0 qla2xxx                  sdk       SP A1     active  alive       0      0

 

Pseudo name=emcpowerb

CLARiiON ID=FCNCX093300010 [Storage Group 2]

Logical device ID=600601601EA02500F22E8FC2207AE111 [LUN 11]

state=alive; policy=BasicFailover; priority=0; queued-IOs=0; 

Owner: default=SP A, current=SP A       Array failover mode: 1

==============================================================================

--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---

###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors

==============================================================================

   0 qla2xxx   www.2cto.com   sdg       SP B1     active  alive       0      0

   0 qla2xxx                  sdl       SP A1     active  alive       0      0

 

Pseudo name=emcpowerc

CLARiiON ID=FCNCX093300010 [Storage Group 2]

Logical device ID=600601601EA02500FA322E81207AE111 [LUN 1]

state=alive; policy=BasicFailover; priority=0; queued-IOs=0; 

Owner: default=SP A, current=SP A       Array failover mode: 1

==============================================================================

--------------- Host ---------------   - Stor -   -- I/O Path --  -- Stats ---

###  HW Path               I/O Paths    Interf.   Mode    State   Q-IOs Errors

==============================================================================

   0 qla2xxx                  sdc       SP B1     active  alive       0      0

   0 qla2xxx                  sdi       SP A1     active  alive       0      0

如上红色字体显示的,我们可以清楚的看到对于两台主机LUN对应的情况如下:

DBTEST1                                 DBTEST2

/dev/emcpowera                   /dev/emcpowerb

/dev/emcpowerb                   /dev/emcpowera

/dev/emcpowerc                  /dev/emcpowerc

本次由于安装RAC,根据规划,emcpowerb和emcpowerc分别为OCR disk和voting disk, 而emcpowera为datadg磁盘组  www.2cto.com  

对于如问题我们可以处理的思路如下:

1.采用powerpath软件的管理命令可以将其伪设备名称修改为一致,具体可以参照DBTEST1的名称,在DBTEST2上做如下修改:

#emcpadm renamepseudo �Cs emcpowera �Ct emcpowerd

#emcpadm renamepseudo �Cs emcpowerb �Ct emcpowera

#emcpadm renamepseudo �Cs emcpowerd �Ct emcpowerb

更新配置后,重启下主机看看两端是否还能保持一致。

2.另外我们还可以采用如下方法,也就是保持伪设备名称不变,采用块设备,只需要绑定的raw设备一致即可

                                 DBTEST1                          DBTEST2

/dev/raw/raw3                   /dev/emcpowera                    /dev/emcpowerb

/dev/raw/raw2                   /dev/emcpowerb                    /dev/emcpowera

/dev/raw/raw1                   /dev/emcpowerc                    /dev/emcpowerc

这样在RAC安装过程中只需要在各主机对应raw设备名称就可以了。


你可能感兴趣的:(linux, , ,powerpath,emcpadm)