PadsLogic输出的网表格式:
Part Reference PartType@Part Decals
所以创建网络表时就可以在PCB Footprint中输入:{Source Package}@{PCB Footprint}
最后Pads-PCB建库时,PartType的名称可以与Source Package一样,同个PartType对应不同的Decals,如:
.
R136 R@0402
R137 R@0603
R138 R@0805
.
.
.
C19 C@0603
C20 C@0805
.
.
Q1 Q@TO-92
Q2 Q@SOT-23
.
X1 XTAL@XTAL/S
X2 XTAL@XTAL/U
X3 XTAL@XTAL/3X8
X4 XTAL@XTAL/2X6
X5 XTAL@XTAL/SMD50X32
X6 XTAL@XTAL/SMD70X50
X7 XTAL@OSC4
.
.
U11 S-35390A@S0P8
U12 S-35390A@TSSOP8
.
.
/////////////////////////////////////Attention//////////////////////////////////
导入时的一些错误:
1
Reading file -- D:\Work station\....\PADS2000.asc
*Unspecified or unsupported version of ASCII file
*PADS2000*
Can't find part Type item < BATTERY >
BAT1 BATTERY@BATTERY_SD_10MM
*Bad *PART* ascii data line format
C1 CAP NP@0603
显然是PCB封装库中没有名称为BATTERY和CAP NP的PartType。
2
Reading file -- D:\Work station\....\PADS2000.asc
*Unspecified or unsupported version of ASCII file
*PADS2000*
*Not valid pin name for part type CATHODE
LED5.CATHODE U15.18
*Not valid pin name for part type ANODE
RN23.1 LED5.ANODE
Warning: deleting signal LED0
Warning: deleting signal N362907
**INPUT WARNINGS FOUND**
可能是因为LED5元件的引脚没有PinNumber,
此种情况还可能是因为原理图中用字母形式的PinNumber,而PCB中的PartType中没有给相应引脚分配相应的字母形式的PinNumber
3
Reading file -- D:\Work station\...\SYNCHRO_TEST.asc
*Unspecified or unsupported version of ASCII file
*PADS2000*
Part name already used R1
R1 R@0402
Part name already used R2
R2 R@0402
Part name already used R3
R3 R@0603
Part name already used R4
R4 R@0805
Part name already used R5
R5 R@0805
Part name already used R6
R6 R@0402
Part name already used R7
R7 R@0805
*Bad *CONNECTION* ascii data line format
R4.2 R5.2 R7.2
*Bad *CONNECTION* ascii data line format
R2.1 R1.1 R6.1
*Bad *CONNECTION* ascii data line format
R6.2 R5.1 R3.2 R7.1
*Bad *CONNECTION* ascii data line format
R3.1 R4.1 R1.2 R2.2
**INPUT WARNINGS FOUND**
说明元件已经存在,这样原理图添加新的元件时,PCB导入新生成的网表不会覆盖掉已布局好的元件,
下面就是原理图增加了R8和R9,导入到PCB时的提示信息,对已存在的R1~R7报错,并没有对R8和R9报错,并且也没有打乱掉原来的元件PCB布局!!
////////////////////////////////////////////////////
Reading file -- D:\Work station\OrCAD_Data\Myworks\reference\TEST\SYNCHRO_TEST_2.asc
*Unspecified or unsupported version of ASCII file
*PADS2000*
Part name already used R1
R1 R@0402
Part name already used R2
R2 R@0402
Part name already used R3
R3 R@0603
Part name already used R4
R4 R@0805
Part name already used R5
R5 R@0805
Part name already used R6
R6 R@0402
Part name already used R7
R7 R@0805
*Bad *CONNECTION* ascii data line format
R9.2 R4.2 R5.2 R7.2
*Bad *CONNECTION* ascii data line format
R1.1 R2.1 R8.1 R6.1
*Bad *CONNECTION* ascii data line format
R5.1 R3.2 R6.2 R7.1
*Bad *CONNECTION* ascii data line format
R3.1 R1.2 R4.1 R2.2
**INPUT WARNINGS FOUND**
/////////////////////////////////////////////