<!--DWLayoutEmptyCell--> |
Qlogic光纤卡安装配置相对简单,但是同样的,为了是主机可以识别多个LUN信息,需要修改sd.conf配置文件。
以下是我的sd.conf的配置,供参考:
#
# Copyright (c) 1992, by Sun Microsystems, Inc.
#
#ident "@(#)sd.conf 1.9 98/01/11 SMI"
name="sd" class="scsi" class_prop="atapi"
target=0 lun=0;
name="sd" class="scsi" class_prop="atapi"
target=1 lun=0;
name="sd" class="scsi" class_prop="atapi"
target=2 lun=0;
name="sd" class="scsi" class_prop="atapi"
target=3 lun=0;
name="sd" class="scsi"
target=4 lun=0;
name="sd" class="scsi"
target=5 lun=0;
name="sd" class="scsi"
target=6 lun=0;
name="sd" class="scsi"
target=8 lun=0;
name="sd" class="scsi"
target=9 lun=0;
name="sd" class="scsi"
target=10 lun=0;
name="sd" class="scsi"
target=11 lun=0;
name="sd" class="scsi"
target=12 lun=0;
name="sd" class="scsi"
target=13 lun=0;
name="sd" class="scsi"
target=14 lun=0;
name="sd" class="scsi"
target=15 lun=0;
name="sd" parent="qla2300" target=0 lun=0;
name="sd" parent="qla2300" target=0 lun=1;
name="sd" parent="qla2300" target=0 lun=2;
name="sd" parent="qla2300" target=0 lun=3;
name="sd" parent="qla2300" target=0 lun=4;
name="sd" parent="qla2300" target=0 lun=5;
name="sd" parent="qla2300" target=0 lun=6;
name="sd" parent="qla2300" target=0 lun=7;
name="sd" parent="qla2300" target=1 lun=0;
name="sd" parent="qla2300" target=1 lun=1;
name="sd" parent="qla2300" target=1 lun=2;
name="sd" parent="qla2300" target=1 lun=3;
name="sd" parent="qla2300" target=1 lun=4;
name="sd" parent="qla2300" target=1 lun=5;
name="sd" parent="qla2300" target=1 lun=6;
name="sd" parent="qla2300" target=1 lun=7;
name="sd" parent="qla2300" target=2 lun=0;
name="sd" parent="qla2300" target=3 lun=0;
name="sd" parent="qla2300" target=4 lun=0;
name="sd" parent="qla2300" target=5 lun=0;
name="sd" parent="qla2300" target=6 lun=0;
name="sd" parent="qla2300" target=7 lun=0;
name="sd" parent="qla2300" target=8 lun=0;
name="sd" parent="qla2300" target=9 lun=0;
name="sd" parent="qla2300" target=10 lun=0;
name="sd" parent="qla2300" target=11 lun=0;
name="sd" parent="qla2300" target=12 lun=0;
name="sd" parent="qla2300" target=13 lun=0;
name="sd" parent="qla2300" target=14 lun=0;
name="sd" parent="qla2300" target=15 lun=0;
name="sd" parent="qla2300" target=16 lun=0;
name="sd" parent="qla2300" target=17 lun=0;
name="sd" parent="qla2300" target=17 lun=1;
name="sd" parent="qla2300" target=17 lun=2;
name="sd" parent="qla2300" target=17 lun=3;
|
配置完成以后,使用reboot -- -r选项重新启动主机系统,之后可以正常发现分配给主机系统的多个LUN。
# format
Searching for disks...done
c2t2d0: configured with capacity of 133.21GB
c2t2d1: configured with capacity of 266.41GB
c2t2d2: configured with capacity of 199.81GB
c2t2d3: configured with capacity of 60.00GB
c2t2d4: configured with capacity of 1023.94MB
c2t2d5: configured with capacity of 133.21GB
c2t2d6: configured with capacity of 60.00GB
c2t2d7: configured with capacity of 1023.94MB
c2t3d0: configured with capacity of 133.21GB
c2t3d1: configured with capacity of 266.41GB
c2t3d2: configured with capacity of 199.81GB
c2t3d3: configured with capacity of 60.00GB
c2t3d4: configured with capacity of 1023.94MB
c2t3d5: configured with capacity of 133.21GB
c2t3d6: configured with capacity of 60.00GB
c2t3d7: configured with capacity of 1023.94MB
c3t2d0: configured with capacity of 133.21GB
c3t2d1: configured with capacity of 266.41GB
c3t2d2: configured with capacity of 199.81GB
c3t2d3: configured with capacity of 60.00GB
c3t2d4: configured with capacity of 1023.94MB
c3t2d5: configured with capacity of 133.21GB
c3t2d6: configured with capacity of 60.00GB
c3t2d7: configured with capacity of 1023.94MB
c3t3d0: configured with capacity of 133.21GB
c3t3d1: configured with capacity of 266.41GB
c3t3d2: configured with capacity of 199.81GB
c3t3d3: configured with capacity of 60.00GB
c3t3d4: configured with capacity of 1023.94MB
c3t3d5: configured with capacity of 133.21GB
c3t3d6: configured with capacity of 60.00GB
c3t3d7: configured with capacity of 1023.94MB
emcpower0a: configured with capacity of 133.21GB
emcpower1a: configured with capacity of 1023.94MB
emcpower2a: configured with capacity of 60.00GB
emcpower3a: configured with capacity of 133.21GB
emcpower4a: configured with capacity of 1023.94MB
emcpower5a: configured with capacity of 60.00GB
emcpower6a: configured with capacity of 199.81GB
emcpower7a: configured with capacity of 266.41GB
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <sun72g sec hd alt cyl>
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e01077a8d1,0
1. c1t1d0 <sun72g sec hd alt cyl>
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e01077cb01,0
2. c1t2d0 <sun72g sec hd alt cyl>
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0107823d1,0
3. c1t3d0 <sun72g sec hd alt cyl>
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e010782471,0
4. c1t4d0 <sun72g sec hd alt cyl>
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0107a6b21,0
5. c1t5d0 <sun72g sec hd alt cyl>
/pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0107aacc1,0
6. c2t2d0 <dgc-raid5-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@2,0
7. c2t2d1 <dgc-raid5-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@2,1
8. c2t2d2 <dgc-raid5-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@2,2
9. c2t2d3 <dgc-raid1-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@2,3
10. c2t2d4 <dgc-raid1-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@2,4
11. c2t2d5 <dgc-raid5-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@2,5
12. c2t2d6 <dgc-raid1-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@2,6
13. c2t2d7 <dgc-raid1-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@2,7
14. c2t3d0 <dgc-raid5-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@3,0
15. c2t3d1 <dgc-raid5-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@3,1
16. c2t3d2 <dgc-raid5-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@3,2
17. c2t3d3 <dgc-raid1-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@3,3
18. c2t3d4 <dgc-raid1-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@3,4
19. c2t3d5 <dgc-raid5-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@3,5
20. c2t3d6 <dgc-raid1-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@3,6
21. c2t3d7 <dgc-raid1-0206 sec hd alt cyl>
/pci@9,700000/fibre-channel@4/sd@3,7
22. c3t2d0 <dgc-raid5-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@2,0
23. c3t2d1 <dgc-raid5-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@2,1
24. c3t2d2 <dgc-raid5-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@2,2
25. c3t2d3 <dgc-raid1-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@2,3
26. c3t2d4 <dgc-raid1-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@2,4
27. c3t2d5 <dgc-raid5-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@2,5
28. c3t2d6 <dgc-raid1-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@2,6
29. c3t2d7 <dgc-raid1-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@2,7
30. c3t3d0 <dgc-raid5-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@3,0
31. c3t3d1 <dgc-raid5-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@3,1
32. c3t3d2 <dgc-raid5-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@3,2
33. c3t3d3 <dgc-raid1-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@3,3
34. c3t3d4 <dgc-raid1-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@3,4
35. c3t3d5 <dgc-raid5-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@3,5
36. c3t3d6 <dgc-raid1-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@3,6
37. c3t3d7 <dgc-raid1-0206 sec hd alt cyl>
/pci@8,700000/fibre-channel@4/sd@3,7
38. emcpower0a <dgc-raid5-0206 sec hd alt cyl>
/pseudo/emcp@0
39. emcpower1a <dgc-raid1-0206 sec hd alt cyl>
/pseudo/emcp@1
40. emcpower2a <dgc-raid1-0206 sec hd alt cyl>
/pseudo/emcp@2
41. emcpower3a <dgc-raid5-0206 sec hd alt cyl>
/pseudo/emcp@3
42. emcpower4a <dgc-raid1-0206 sec hd alt cyl>
/pseudo/emcp@4
43. emcpower5a <dgc-raid1-0206 sec hd alt cyl>
/pseudo/emcp@5
44. emcpower6a <dgc-raid5-0206 sec hd alt cyl>
/pseudo/emcp@6
45. emcpower7a <dgc-raid5-0206 sec hd alt cyl>
/pseudo/emcp@7
Specify disk (enter its number): 1
selecting c1t1d0
[disk formatted]
FORMAT MENU:
disk - select a disk
type - select (define) a disk type
partition - select (define) a partition table
current - describe the current disk
format - format and analyze the disk
repair - repair a defective sector
label - write label to the disk
analyze - surface analysis
defect - defect list management
backup - search for backup labels
verify - read and display labels
save - save new disk/partition definitions
inquiry - show vendor, product and revision
volname - set 8-character volume name
!<cmd> - execute <cmd>, then return
quit
format> q
#
</cmd></cmd></dgc-raid5-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid5-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid5-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid5-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid1-0206></dgc-raid1-0206></dgc-raid5-0206></dgc-raid5-0206></dgc-raid5-0206></sun72g></sun72g></sun72g></sun72g></sun72g></sun72g>
|
使用powerpath查看通路状态:
# powermt display dev=all
Pseudo name=emcpower6a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A91000004B1E21C02FD911 [LUN 5]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4 c2t2d2s0 SP A1 active alive 0 0
1281 pci@9/fibre-channel@4 c2t3d2s0 SP B1 active alive 0 0
1280 pci@8/fibre-channel@4 c3t2d2s0 SP A0 active alive 0 0
1280 pci@8/fibre-channel@4 c3t3d2s0 SP B0 active alive 0 0
Pseudo name=emcpower3a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A910002070EBBEBF2FD911 [LUN 2]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4 c2t2d5s0 SP A1 active alive 0 0
1281 pci@9/fibre-channel@4 c2t3d5s0 SP B1 active alive 0 0
1280 pci@8/fibre-channel@4 c3t2d5s0 SP A0 active alive 0 0
1280 pci@8/fibre-channel@4 c3t3d5s0 SP B0 active alive 0 0
Pseudo name=emcpower1a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A9100030349D70BF2FD911 [LUN 0]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4 c2t2d7s0 SP A1 active alive 0 0
1281 pci@9/fibre-channel@4 c2t3d7s0 SP B1 active alive 0 0
1280 pci@8/fibre-channel@4 c3t2d7s0 SP A0 active alive 0 0
1280 pci@8/fibre-channel@4 c3t3d7s0 SP B0 active alive 0 0
Pseudo name=emcpower5a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A9100034F5B208C02FD911 [LUN 4]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4 c2t2d3s0 SP A1 active alive 0 0
1281 pci@9/fibre-channel@4 c2t3d3s0 SP B1 active alive 0 0
1280 pci@8/fibre-channel@4 c3t2d3s0 SP A0 active alive 0 0
1280 pci@8/fibre-channel@4 c3t3d3s0 SP B0 active alive 0 0
Pseudo name=emcpower2a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A9100050F80AA1BF2FD911 [LUN 1]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4 c2t2d6s0 SP A1 active alive 0 0
1281 pci@9/fibre-channel@4 c2t3d6s0 SP B1 active alive 0 0
1280 pci@8/fibre-channel@4 c3t2d6s0 SP A0 active alive 0 0
1280 pci@8/fibre-channel@4 c3t3d6s0 SP B0 active alive 0 0
Pseudo name=emcpower7a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A910005CD3952EC02FD911 [LUN 6]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4 c2t2d1s0 SP A1 active alive 0 0
1281 pci@9/fibre-channel@4 c2t3d1s0 SP B1 active alive 0 0
1280 pci@8/fibre-channel@4 c3t2d1s0 SP A0 active alive 0 0
1280 pci@8/fibre-channel@4 c3t3d1s0 SP B0 active alive 0 0
Pseudo name=emcpower4a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A910007EFC11F4BF2FD911 [LUN 3]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4 c2t2d4s0 SP A1 active alive 0 0
1281 pci@9/fibre-channel@4 c2t3d4s0 SP B1 active alive 0 0
1280 pci@8/fibre-channel@4 c3t2d4s0 SP A0 active alive 0 0
1280 pci@8/fibre-channel@4 c3t3d4s0 SP B0 active alive 0 0
Pseudo name=emcpower0a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A9100096E1432DC62FD911 [LUN 7]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP B
==============================================================================
---------------- Host --------------- - Stor - -- I/O Path - -- Stats ---
### HW Path I/O Paths Interf. Mode State Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4 c2t2d0s0 SP A1 active alive 0 0
1281 pci@9/fibre-channel@4 c2t3d0s0 SP B1 active alive 0 0
1280 pci@8/fibre-channel@4 c3t2d0s0 SP A0 active alive 0 0
1280 pci@8/fibre-channel@4 c3t3d0s0 SP B0 active alive 0 0
|
作为对比,你可以参考一下Emulex光纤卡的配置方法:
http://www.eygle.com/unix/Emulex_LightPulse_FC9002L_Solaris9_Install.htm
本文作者: eygle,Oracle技术关注者,来自中国最大的Oracle技术论坛itpub. www.eygle.com是作者的个人站点.你可通过[email protected]来联系作者.欢迎技术探讨交流以及链接交换.
原文出处:
http://www.eygle.com/unix/Qlogic.HBA.Config.log.htm
|