The record of Rf module debugging (1)

In order to improve engineering English writing ability,start from today,record my daily work of  electronic designer。

The record of Rf module debugging (1)_第1张图片
The record of Rf module debugging (1)_第2张图片

today,I  have test alternative NPN Transistor foe TX Module,The following is the process of debugging the spectrometer。

Environment seting:

frequency:433.92Mhz

span:200Khz   (It means  that theband width,according the datasheet)

offset:deviation compensation (when  the instrument in not accurate ,we need to use it )

Sweep Time: 1s (when we give the tx module ahigh-frequency signal, we should  set a long time,such as 1 second)

Ref level:10dbm ( refer to datasheet for tx module )

(1)power test (TX module 433.92)

press the peak search,and reading the power valves。

(2)frequency deviation test  (2sc3356 npn transistor & mas4901 )

maker ->  Normal -> 433.92Mhz -> delta-> per search.

(3) harmonic test (The general situation requires 5 data )

frequency->  cf.step-> input 433.92Mhz-> press UP or Down—> per search

3  Effect drawing .

ok, that's over. next step. I need to test 20 sample . wish me good luck.