C3500XL Boot Loader (C3500-HBOOT-M) Version 12.0(5.3)WC(1), MAINTENANCE INTERIM SOFTWARE
Compiled Mon 30-Apr-01 07:51 by devgoyal
starting…
Base ethernet MAC Address: 00:07:eb:c1:9f:40
Xmodem file system is available.

The system has been interrupted prior to initializing the
flash filesystem.  The following commands will initialize
the flash filesystem, and finish loading the operating
system software:

    flash_init
    load_helper
    boot

switch: flash_init                               初始化flash
Initializing Flash…
flashfs[0]: 163 files, 2 directories
flashfs[0]: 0 orphaned files, 0 orphaned directories
flashfs[0]: Total bytes: 3612672
flashfs[0]: Bytes used: 3608064
flashfs[0]: Bytes available: 4608
flashfs[0]: flashfs fsck took 5 seconds.
…done Initializing Flash.
Boot Sector Filesystem (bs:) installed, fsid: 3
Parameter Block Filesystem (pb:) installed, fsid: 4
switch: dir

List of filesystems currently registered:
               flash[0]: (read-write)
              xmodem[1]: (read-only)
                null[2]: (read-write)
                  bs[3]: (read-only)
switch: dir flash:                   查看flash
Directory of flash:/

2    -rwx  1803944   <date>               cisco.bin
3    -rwx  676       <date>               vlan.dat
4    drwx  10176     <date>               html
5    -rwx  1279      <date>               config.text
6    -rwx  516096    <date>               li.bin

4608 bytes available (3608064 bytes used)            
*** line too large ***

switch: rename flash:/config.text flash:/config.old
switch:
switch:
switch:
switch: dir flash:
Directory of flash:/

2    -rwx  1803944   <date>               cisco.bin
3    -rwx  676       <date>               vlan.dat
4    drwx  10176     <date>               html
5    -rwx  1279      <date>               config.old
6    -rwx  516096    <date>               li.bin

4608 bytes available (3608064 bytes used)
switch: ?
           ? ― Present list of available commands
        boot ― Load and boot an executable image
         cat ― Concatenate (type) file(s)
        copy ― Copy a file
      delete ― Delete file(s)
         dir ― List files in directories
  flash_init ― Initialize flash filesystem(s)
      format ― Format a filesystem
        fsck ― Check filesystem consistency
        help ― Present list of available commands
load_helper ― Load and initialize a helper image
      memory ― Present memory heap utilization information
       mkdir ― Create dir(s)
        more ― Concatenate (display) file(s)
      rename ― Rename a file
       reset ― Reset the system
       rmdir ― Delete empty dir(s)
         set ― Set or display environment variables
   set_param ― Set system parameters in flash
       sleep ― Sleep a specified number of seconds
        trap ― Cause a software breakpoint to occur
        type ― Concatenate (type) file(s)
       unset ― Unset one or more environment variables
     version ― Display boot loader version
switch: boot            重新启动交换机
Loading
“flash:cisco.bin”…###############################################################################################################################
#######################################################
File “flash:cisco.bin” uncompressed and installed, entry point: 0×3000
executing…
              Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software �C Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
           cisco Systems, Inc.
           170 West Tasman Drive
           San Jose, California 95134-1706
Cisco Internetwork Operating System Software
IOS ™ C3500XL Software (C3500XL-C3H2S-M), Version 12.0(5)WC9, RELEASE SOFTWARE (fc1)
Copyright (c) 1986-2003 by cisco Systems, Inc.
Compiled Fri 19-Sep-03 10:01 by antonino
Image text-base: 0×00003000, data-base: 0×0034E434

Initializing C3500XL flash…
flashfs[1]: 163 files, 2 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 3612672
flashfs[1]: Bytes used: 3608064
flashfs[1]: Bytes available: 4608
flashfs[1]: flashfs fsck took 5 seconds.
flashfs[1]: Initialization complete.
…done Initializing C3500XL flash.
C3500XL POST: System Board Test: Passed
C3500XL POST: Daughter Card Test: Passed
C3500XL POST: CPU Buffer Test: Passed
C3500XL POST: CPU Notify RAM Test: Passed
C3500XL POST: CPU Interface Test: Passed
C3500XL POST: Testing Switch Core: Passed
C3500XL POST: Testing Buffer Table: Passed
C3500XL POST: Data Buffer Test: Passed
C3500XL POST: Configuring Switch Parameters: Passed
C3500XL POST: Ethernet Controller Test: Passed
C3500XL POST: MII Test: Passed
cisco WS-C3524-XL (PowerPC403) processor (revision 0×01) with 8192K/1024K bytes of memory.
Processor board ID FAB0546Q2GQ, with hardware revision 0×00
Last reset from power-on

Processor is running Enterprise Edition Software
Cluster command switch capable
Cluster member switch capable
24 FastEthernet/IEEE 802.3 interface(s)
2 Gigabit Ethernet/IEEE 802.3 interface(s)

32K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address: 00:07:EB:C1:9F:40
Motherboard assembly number: 73-3904-12
Power supply part number: 34-0851-02
Motherboard serial number: FAB05462EKG
Power supply serial number: PHI0538003G
Model revision number: A0
Motherboard revision number: A0
Model number: WS-C3524-XL-EN
System serial number: FAB0546Q2GQ
C3500XL INIT: Complete

00:00:21: %SYS-5-RESTART: System restarted �C
Cisco Internetwork Operating System Software
IOS ™ C3500XL Software (C3500XL-C3H2S-M), Version 12.0(5)WC9, RELEASE SOFTWARE (fc1)
Copyright (c) 1986-2003 by cisco Systems, Inc.
Compiled Fri 19-Sep-03 10:01 by antonino

         ― System Configuration Dialog ―

At any point you may enter a question mark ‘?’ for help.
Use ctrl-c to abort configuration dialog at any prompt.
Default settings are in square brackets ‘[]‘.

Continue with configuration dialog? [yes/no]: n
Press RETURN to get started.

Switch>en
Switch#config t
Enter configuration commands, one per line.  End with CNTL/Z.
Switch(config)#no enable password     删除enable密码
Switch(config)#no enable secret
Switch(config)#end
Switch#copy running-config startup-config
Destination filename [startup-config]?
Building configuration…
[OK]
Switch#dir flash:
Directory of flash:/

  2  -rwx     1803944   Mar 01 1993 00:07:18  cisco.bin
  3  -rwx         676   Mar 01 1993 01:33:19  vlan.dat
  4  drwx       10176   Mar 01 1993 00:08:09  html
  5  -rwx        1279   Mar 01 1993 01:08:39  config.old
  6  -rwx      516096   Mar 01 1993 00:20:39  li.bin
166  -rwx        1056   Mar 01 1993 00:02:19  config.text

3612672 bytes total (3072 bytes free)
Switch#dele
Switch#delete flash:/config.lod
Delete filename [config.lod]?
Delete flash:/config.lod? [confirm]
%Error deleting flash:/config.lod (No such file or directory)
Switch#delete flash:/config.old
Delete filename [config.old]?
Delete flash:/config.old? [confirm]
Switch#dir
Directory of flash:/

  2  -rwx     1803944   Mar 01 1993 00:07:18  cisco.bin
  3  -rwx         676   Mar 01 1993 01:33:19  vlan.dat
  4  drwx       10176   Mar 01 1993 00:08:09  html
  6  -rwx      516096   Mar 01 1993 00:20:39  li.bin
166  -rwx        1056   Mar 01 1993 00:02:19  config.text
3612672 bytes total (4608 bytes free)