cacti不出图问题

CMDPHP: Poller[0] WARNING: SNMP Get Timeout for Host:'', and OID


监控一台windwos 2008 R2服务器,但是出现了各种的问题。开始是cpu、硬盘、内存、网卡都有图没有流量,开始一个一个的解决。。


下面的图片是在监控硬盘时报的错误和解决办法



报错图片:


dbb44aed2e738bd4327f0819a08b87d6277ff9b8



解决办法:


1.设置---采集器--每个SNMP获取请求的OID数量(由原来的10改成了50)


2.主机--找到报错的那个主机,点开以后在--获取请求的最大OID(由原来的10改成了50


32fa828ba61ea8d3dc2dd12c960a304e251f588e


3.修改完之后查看图形,果然出图了。。


f11f3a292df5e0fe9e7b2c295d6034a85edf72b2




参考文章:


tianlaowu
WARNING: SNMP timeout detected [500 ms]

For "reasonable" timeouts, this may be related to a snmpbulkwalk issue. To change this, see Settings, Poller and lower the value for The Maximum SNMP OID's Per SNMP Get Request.  Start at a value of 10 and increase it again, if the poller starts  working. Some agent's don't have the horsepower to deliver that many  OID's at a time. Therefore, we can reduce the number for those  older/underpowered devices.

增加了The Maximum SNMP OID's Per SNMP Get Request 的值,默认为10,我增加到了30(可以适当调大),其中的一台服务器正常了,但是,还有其他的服务器仍然不出图。

对于仍然不出图的服务器,在console-management-devices里选择不出图的服务器,修改里面的Maximum OID's Per Get Request选项,增加到30(在此之前这里还是默认的10.)


最后,我更改了setting里的Maximum Threads per Process 和 Maximum Concurrent Poller Processes为5,默认为1.

使用0.8.7c没有问题,升级倒出问题了~~


转载需说明出处http://hi.baidu.com/myl231/item/d44c1f5712750ac3d2e10c28