STM32的内部温度传感器

1、STM32的内部温度传感器
   STM32内部温度传感器与ADC的通道16相连,与ADC配 合使用实现温度测量。测量范围–40~125℃,精度 ± 1.5℃
操作流程:
   1)、设置ADC相关参数
   // ADC1 configuration -----------------------------
   ADC_InitStructure.ADC_Mode = ADC_Mode_Independent;
   ADC_InitStructure.ADC_ScanConvMode = ENABLE;
   ADC_InitStructure.ADC_ContinuousConvMode = ENABLE;
   ADC_InitStructure.ADC_ExternalTrigConv = ADC_ExternalTrigConv_None;
   ADC_InitStructure.ADC_DataAlign = ADC_DataAlign_Right;
   ADC_InitStructure.ADC_NbrOfChannel = 1;
   ADC_Init(ADC1, &ADC_InitStructure);
   2)、选中ADC1的通道16作为输入,设置采样时间17.1us ( Ncycle × tADC = 17.1靤 )。
   // ADC1 regular channel16 Temp Sensor configuration
   ADC_RegularChannelConfig(ADC1, ADC_Channel_16, 1, ADC_SampleTime_55Cycles5);
   3)、设置寄存器ADC_CR2中的TSVREFE位激活温度传感器
   // Enable the temperature sensor and vref internal channel
   ADC_TempSensorVrefintCmd(ENABLE);
   4)、转换采样值为温度
   ADC转换结束以后,读取ADC_DR寄存器中的结果,转换温度值计算公式如下:
           V25 - VSENSE
   T(℃) = ------------  + 25
            Avg_Slope
      V25:  温度传感器在25℃时 的输出电压,典型值1.43 V。
     VSENSE:温度传感器的当前输出电压,与ADC_DR 寄存器中的结果ADC_ConvertedValue之间的转换关系为: 
                       ADC_ConvertedValue * Vdd
             VSENSE = --------------------------
                       Vdd_convert_value(0xFFF)
     Avg_Slope:温度传感器输出电压和温度的关联参数,典型值4.3 mV/℃。
     //Converted Temperature
     Vtemp_sensor = ADC_ConvertedValue * Vdd / Vdd_convert_value;
     Current_Temp = (V25 - Vtemp_sensor)/Avg_Slope + 25;
2、VDDA的电压范围
    STM32的数据手册规定,VDD与VDDA之间的压差不能大于300mV。ADC的工作电压范围在2.4V~3.6V,供电电压VDD范围在2.0V~3.6V.